Medium frequency topology in railway applications

Steiner, Michael, Reinold, Harry · 2007 · 2007 European Conference on Power Electronics and Applications

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The proposed Medium Frequency Topology is replacing the bulky main line transformer on board of railway vehicles. Especially in countries with 15 kV railway power supply, the low frequency of 16.7 Hz is leading to huge and heavy transformers. Today's Transformers are often minimized in weight and volume, which leads to significantly high transformer losses compared with distribution transformers. The Medium Frequency Topology is the power electronic solution that considerably reduces weight and losses of the traction system.

Overview

Integrity signals

Registry

Crossref · 10.1109/epe.2007.4417570

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 6 references

Research works printed but not linked: 8

  1. umbricht, 2000, Medium Frequency Transformer
  2. berth, 1998, Hochspannungsisolationssystem
  3. kratz, 0, Antriebskonzepte für zukünftige elektrische Triebfahrzeuge, eb 11/98
  4. steiner, 2000, Seriegeschaltete Gleichspannungszwischenkreis-umrichter in Traktionsanwendungen Am Wechselspannungs-fahrdraht
  5. steiner, 1996, Antriebssystem für ein Schienenfahrzeug und Ansteuerverfahren hierzu
  6. engel, 2003, Elektronik statt Eisen: der Alstom “e-transformator, Eisenbahn Revuew 8–9
  7. menniken, 1978, Stromrichtersystem mit Wechselspannungszwischenkreis und seine Anwendung in der Traktionstechnik
  8. steiner, 1998, Antriebsschaltung für ein Schienenfahrzeug DE

Cited by

See all 283

Metadata

Authors
Steiner, M., & Reinold, H.
Affiliations
Bombardier (Germany) (DE)
Venue
2007 European Conference on Power Electronics and Applications
Publisher
IEEE
Published
2007
Pages
1-10
OpenAlex
W2536628707
Cited by
249
References
6
Citations by year
2026: 6 · 2025: 6 · 2024: 9 · 2023: 17 · 2022: 12 · 2021: 17 · 2020: 13 · 2019: 22 · 2018: 25 · 2017: 23 · 2016: 15 · 2015: 13 · 2014: 16 · 2013: 10 · 2012: 17
FWCI
8.04
Type
conference paper
Language
en
Open access
closed
Locations
European Conference on Power Electronics and Applications (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
  • Social Sciences › Transportation › Railway Systems and Energy Efficiency
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
railway traction systems, transformer losses, power converters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medium frequency topology in railway applications. https://app.cochat.ai/papers/10.1109/epe.2007.4417570
The paper
Steiner, M., & Reinold, H. (2007). Medium frequency topology in railway applications. 2007 European Conference on Power Electronics and Applications. https://doi.org/10.1109/epe.2007.4417570

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.