CoChat

Calculation of power losses for MMC-based VSC HVDC stations

Jones, Phil S., Davidson, Colin C. · 2013 · 2013 15th European Conference on Power Electronics and Applications (EPE)
Cited by 129

The DOI matches its Crossref record.

Abstract

VSC technology is now well established in HVDC and is, in many respects, complementary to the older Line Commutated Converter (LCC) technology. Many advantages have been claimed for VSC technology in HVDC, including the smaller site footprint. On the other hand, VSC HVDC stations have higher power losses than LCC stations. Although the relative advantages and disadvantages are well known within the industry, there have been very few attempts to quantify these factors on an objective basis. In part, this is because of the lack of applicable standards for determining the power losses of a VSC station. No equivalent of IEC 61803 is today available for VSC-HVDC, but now a draft IEC standard (IEC 62751) is in preparation, which will permit objective comparisons to be made between power losses of LCC and VSC stations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/epe.2013.6631955

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 129

Metadata

Authors
Jones, P. S., & Davidson, C. C.
Venue
2013 15th European Conference on Power Electronics and Applications (EPE)
Publisher
IEEE
Published
2013-09
Pages
1-10
OpenAlex
W2077452379
Cited by
129
References
0
FWCI
10.99
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Calculation of power losses for MMC-based VSC HVDC stations. https://app.cochat.ai/papers/10.1109/epe.2013.6631955
The paper
Jones, P. S., & Davidson, C. C. (2013). Calculation of power losses for MMC-based VSC HVDC stations. 2013 15th European Conference on Power Electronics and Applications (EPE). https://doi.org/10.1109/epe.2013.6631955

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.