Spatially distributed tactile feedback for kinesthetic motion guidance
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Apraxic stroke patients need to perform repetitive arm movements to regain motor functionality, but they struggle to process the visual feedback provided by typical virtual rehabilitation systems. Instead, we imagine a low cost sleeve that can measure the movement of the upper limb and provide tactile feedback at key locations. The feedback provided by the tactors should guide the patient through a series of desired movements by allowing him or her to feel limb configuration errors at each instant in time. After discussing the relevant motion capture and actuator options, this paper describes the design and programming of our current prototype, a wearable tactile interface that uses magnetic motion tracking and shaftless eccentric mass motors. The sensors and actuators are attached to the sleeve of an athletic shirt with novel plastic caps, which also help focus the vibration on the user's skin. We connect the motors in current drive for improved performance, and we present a full parametric model for their in situ dynamic response (acceleration output given current input).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Virtual Environments for Motor Rehabilitation: Review
Holden, M. K. (2005) · CyberPsychology & Behavior · doi:10.1089/cpb.2005.8.187 · Cited by 1,154
TIKL: Development of a Wearable Vibrotactile Feedback Suit for Improved Human Motor Learning
Lieberman, J., & Breazeal, C. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.907481 · Cited by 272 · cited 3×
“Restrictions apply. is similar to Lieberman and Breazeal [14] and is in contrast to the Cartesian collision paradigm chosen by Bloomfield and Badler [4].”
Cited by
Skin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
A wireless haptic interface for programmable patterns of touch across large areas of the skin
Jung, Y. H., Yoo, J.-Y., Vázquez-Guardado, A., Kim, J.-H., Kim, J.-T., Luan, H., Park, M., Lim, J., Shin, H.-S., Su, C.-J., et al. (2022) · Nature Electronics · doi:10.1038/s41928-022-00765-3 · Cited by 263
Haptic wearables as sensory replacement, sensory augmentation and trainer – a review
Shull, P. B., & Damian, D. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0055-z · Cited by 245
Lessons in using vibrotactile feedback to guide fast arm motions
Bark, K., Khanna, P., Irwin, R., Kapur, P., Jax, S. A., Buxbaum, L. J., & Kuchenbecker, K. J. (2011) · 2011 IEEE World Haptics Conference · doi:10.1109/whc.2011.5945512 · Cited by 63
“Other applications using similar methodologies include dance training [2], stroke rehabilitation [4,5], rowing [8,13], gait retraining [9], and snowboarding [11].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Kapur, P., Jensen, M., Buxbaum, L. J., Jax, S. A., & Kuchenbecker, K. J.
- Venue
- 2010 IEEE Haptics Symposium
- Publisher
- IEEE
- Published
- 2010-03
- Pages
- 519-526
- ISSN
- 2324-7347 (ISSN-L)
- OpenAlex
- W2137923919
- Cited by
- 72
- References
- 2
- FWCI
- 10.37
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.