Assessing Cognitive Load with Physiological Sensors
The DOI matches its Crossref record.
Abstract
Assessing the cognitive load of a subject performing a computer task using task performance data is normally available at the end of the task. For assessing cognitive load, physiological data has the advantage of being available in real-time and the potential of assessing the affective components of cognitive load. Described are two new methods of assessing cognitive load from eye tracking and the pressures a subject applies to a computer mouse when subjects perform a math task that involves moving targets. Physiological measures that significantly discriminated task difficulty included eye movement, skin conductivity and one of the pressure signals from the computer mouse. Also, in some cases, these physiological measures can be more sensitive than task performance measures of cognitive load (i.e., incorrect actions) to detect interaction effects with task difficulty. The suite of physiological sensors is shown to be a viable alternative or supplement to task performance measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Psycho-physiological measures for assessing cognitive load
Haapalainen, E., Kim, S., Forlizzi, J. F., & Dey, A. K. (2010) · Proceedings of the 12th ACM international conference on Ubiquitous computing · doi:10.1145/1864349.1864395 · Cited by 382
A Survey on Measuring Cognitive Workload in Human-Computer Interaction
Kosch, T., Karolus, J., Zagermann, J., Reiterer, H., Schmidt, A., & Woźniak, P. W. (2023) · ACM Computing Surveys · doi:10.1145/3582272 · Cited by 304
“However, previous research has shown that various eye movements can also indicate increased cognitive demand [63, 131, 133] or derive the user proficiency during interaction [151].”
Using psycho-physiological measures to assess task difficulty in software development
Fritz, T., Begel, A., Müller, S. C., Yigit-Elliott, S., & Züger, M. (2014) · Proceedings of the 36th International Conference on Software Engineering · doi:10.1145/2568225.2568266 · Cited by 262
“Measure Previously found effect Eyetracking Pupil size Cognitive load [28, 40] Memory load [7]; Mental workload [36] Saccades Mental workload while air traffic control tasks [15]; Evaluation of user interfaces [24] Fixations Cognitive load while solving arithmetical tasks [35]; Performance during a code review [73, 65…”
BackgroundUsing galvanic skin response for cognitive load measurement in arithmetic and reading tasks
Nourbakhsh, N., Wang, Y., Chen, F., & Calvo, R. A. (2012) · Proceedings of the 24th Australian Computer-Human Interaction Conference · doi:10.1145/2414536.2414602 · Cited by 219
“To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee.”
BackgroundApplication of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
“Ikehara and Crosby [97] used physiological sensors to assess cognitive load.”
Metadata
- Authors
- Ikehara, C. S., & Crosby, M. E.
- Venue
- Proceedings of the 38th Annual Hawaii International Conference on System Sciences
- Publisher
- IEEE
- Published
- 2005-04-01
- Pages
- 295a-295a
- ISSN
- 1530-1605 (ISSN-L)
- OpenAlex
- W2111517084
- Cited by
- 150
- References
- 0
- FWCI
- 5.32
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing Cognitive Load with Physiological Sensors. https://app.cochat.ai/papers/10.1109/hicss.2005.103
- The paper
- Ikehara, C. S., & Crosby, M. E. (2005). Assessing Cognitive Load with Physiological Sensors. Proceedings of the 38th Annual Hawaii International Conference on System Sciences. https://doi.org/10.1109/hicss.2005.103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.