On line thermal model and thermal management strategy of a three phase voltage source inverter
The DOI matches its Crossref record.
Abstract
A third order dynamical thermal model suitable for modeling diodes and IGBTs is proposed. The method for deriving model parameters from manufacturers data sheets is derived and verified. Models of the power circuit devices, IGBTs and diodes, together with a heat sink model are combined into a dynamical thermal model of 3-phase inverter bridge. The model, together with thermal management strategy is implemented in a microprocessor. The instantaneous values of junction temperatures of IGBTs and free wheeling diodes (FWDs) are estimated on-line with a one step ahead prediction algorithm. If the temperature on any of the power devices reaches a critical value, the PWM frequency is reduced or the PWM method changed in order to reduce losses. If switching losses are still too high and minimum allowable switching frequency is reached; the thermal model starts to reduce inverter current in order to keep the junction temperature of the hottest device of the power circuit below a critical level. The dynamical model with thermal management strategy becomes most useful at low frequency, i.e. stall speed like operation of the drive with high instantaneous loading on particular devices in the power circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
The Active NPC Converter and Its Loss-Balancing Control
Bruckner, T., Bernet, S., & Guldner, H. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.847586 · Cited by 731
Junction Temperature Control for More Reliable Power Electronics
Andresen, M., Ma, K., Buticchi, G., Falck, J., Blaabjerg, F., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665697 · Cited by 345
Active thermal control of power electronic modules
Murdock, D. A., Torres, J. E. R., Connors, J. J., & Lorenz, R. D. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.863905 · Cited by 332
Overview of Real-Time Lifetime Prediction and Extension for SiC Power Converters
Ni, Z., Lyu, X., Yadav, O. P., Singh, B. N., Zheng, S., & Cao, D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2962503 · Cited by 261
Metadata
- Authors
- Blasko, V., Lukaszewski, R., & Sladky, R.
- Venue
- Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370)
- Publisher
- IEEE
- Published
- 2003-01-20
- Volume
- 2
- Pages
- 1423-1431
- OpenAlex
- W1962774927
- Cited by
- 126
- References
- 0
- FWCI
- 7.80
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On line thermal model and thermal management strategy of a three phase voltage source inverter. https://app.cochat.ai/papers/10.1109/ias.1999.801687
- The paper
- Blasko, V., Lukaszewski, R., & Sladky, R. (2003). On line thermal model and thermal management strategy of a three phase voltage source inverter. Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370). https://doi.org/10.1109/ias.1999.801687
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.