The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Abstract
This paper discusses the influence of nonsinusoidal flux-waveforms on the remagnetization losses in ferro- and ferrimagnetic materials of inductors, transformers and electrical machines used in power electronic applications. The nonsinusoidal changes of flux originate from driving these devices by nonsinusoidal voltages and currents at different switching frequencies. A detailed examination of a dynamic hysteresis model shows that the physical origin of losses in magnetic material is the average remagnetization velocity rather than the remagnetization frequency. This principle leads to a modification of the most common calculation rule for magnetic core losses, i.e., to the "modified Steinmetz equation" (MSE). In the MSE the remagnetization frequency is replaced by an equivalent frequency which is calculated from the average remagnetization velocity. This approach allows, for the first time, to calculate the losses in the time domain for arbitrary waveforms of flux while using the available set of parameters of the classical Steinmetz equation, DC premagnetization of the material, having a substantial influence on the losses, can also be included. Extensive measurements verify the modified Steinmetz equation presented in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steinmetz, C. P. (1984) · Proceedings of the IEEE · doi:10.1109/proc.1984.12842 · Cited by 656 · cited 1×
“One well-known empirical equation to calculate remagnetization losses traces back to the original work of Steinmetz more than a century ago and is formulated by means of an empirical equation [ 9 ]”
Cited by
Venkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145
Improved calculation of core loss with nonsinusoidal waveforms
Li, J., Abdallah, T., & Sullivan, C. R. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955931 · Cited by 531
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470
Lin, D., Zhou, P., Fu, W. N., Badics, Z., & Cendes, Z. J. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.825025 · Cited by 425
Diekhans, T., & De Doncker, R. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2393912 · Cited by 421
Self-citation
Metadata
- Authors
- Reinert, J., Brockmeyer, A., & De Doncker, R. W.
- Venue
- Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370)
- Publisher
- IEEE
- Published
- 2003-01-20
- Volume
- 3
- Pages
- 2087-2092
- OpenAlex
- W2098352844
- Cited by
- 409
- References
- 1
- FWCI
- 18.87
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation. https://app.cochat.ai/papers/10.1109/ias.1999.806023
- The paper
- Reinert, J., Brockmeyer, A., & De Doncker, R. W. (2003). Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation. Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370). https://doi.org/10.1109/ias.1999.806023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.