Power electronic transformers for utility applications
The DOI matches its Crossref record.
Abstract
The concept of realizing a small size "solid-state" transformer has been discussed for some time. A fairly straightforward approach to accomplish size reduction in a transformer feeding a conventional rectifier-inverter system is to introduce an isolated DC-DC converter in the DC link, isolation being provided by a high frequency transformer. So also, several topologies that employ AC-AC converters connected on primary and secondary sides of a high frequency transformer to reduce the size and weight of the magnetic core have been reported in literature. Such AC-AC converters need switches with bi-directional voltage blocking and current carrying capability, which are commonly realized with pairs of gate turn-off devices such as insulated gate bipolar transistors (IGBT). This paper explores the possibilities of employing AC-AC switched mode power converters in combination with reactive elements to realize a chopped AC link, thereby decreasing the required magnetic core size for voltage transformation and isolation. A primary advantage of this approach is that, the static power converter needs only six devices to implement a three-phase electronic transformer, which makes it an economical solution. Operating principles, magnetic design and other practical issues are discussed. Detailed computer simulations accompanied with experimental verification are presented in the paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
Solid-State Transformers: On the Origins and Evolution of Key Concepts
Huber, J. E., & Kolar, J. W. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2588878 · Cited by 449
Fan, H., & Li, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160652 · Cited by 401
Research on voltage and power balance control for cascaded modular solid-state transformer
Shi, J., Gou, W., Yuan, H., Zhao, T., & Huang, A. Q. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106803 · Cited by 362
Solid-State Transformer Architecture Using AC–AC Dual-Active-Bridge Converter
Qin, H., & Kimball, J. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2204710 · Cited by 310
Metadata
- Authors
- Manjrekar, M. D., Kieferndorf, R., & Venkataramanan, G.
- Venue
- Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129)
- Publisher
- IEEE
- Published
- 2002-11-07
- Volume
- 4
- Pages
- 2496-2502
- OpenAlex
- W1936507428
- Cited by
- 145
- References
- 0
- FWCI
- 3.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Power electronic transformers for utility applications. https://app.cochat.ai/papers/10.1109/ias.2000.883173
- The paper
- Manjrekar, M. D., Kieferndorf, R., & Venkataramanan, G. (2002). Power electronic transformers for utility applications. Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129). https://doi.org/10.1109/ias.2000.883173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.