CoAP-based healthcare sensor networks: A survey
The DOI matches its Crossref record.
Abstract
The Internet of Things (IoT) vision is a hot research topic which enables all kinds of devices to connect together and share information seamlessly. IEEE 802.15.4 Low power Wireless Personal Area Networks (LoWPAN) and IPv6 over LoWPAN (IETF 6LoWPAN) defines standards and protocols for resource constrained Wireless Sensor Networks (WSN). Constrained Application Protocol (CoAP) is an emerging application layer protocol supporting resource constrained devices and easy integration with the existing TCP/IP standards. It is particularly useful for advanced applications in the healthcare field. This paper surveys technologies and techniques for using CoAP-based WSN for connecting and monitoring medical sensors. Application requirements for creating healthcare WSNs utilizing IPv6 and CoAP and real-time monitoring issues are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Internet of Things for Health Care: A Comprehensive Survey
Riazul Islam, S. M., Kwak, D., Humaun Kabir, M., Hossain, M., & Kwak, K.-S. (2015) · IEEE Access · doi:10.1109/access.2015.2437951 · Cited by 3,095
An IoT-Aware Architecture for Smart Healthcare Systems
Catarinucci, L., de Donno, D., Mainetti, L., Palano, L., Patrono, L., Stefanizzi, M. L., & Tarricone, L. (2015) · IEEE Internet of Things Journal · doi:10.1109/jiot.2015.2417684 · Cited by 1,167
“…and smart mobile technologies are leading this evolutionary trend The main objective of this paper is to monitor the heart rate and temperature continuously through heart beat rate sensor and temperature sensor respectively and the respective datas are sent to android device via Bluetooth.”
Remote patient monitoring: a comprehensive study
Malasinghe, L. P., Ramzan, N., & Dahal, K. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-017-0598-x · Cited by 534
A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Bhuiyan, M. N., Rahman, M. M., Billah, M. M., & Saha, D. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3062630 · Cited by 490
Metadata
- Authors
- Khattak, H. A., Ruta, M., & Eugenio Di Sciascio, E.
- Venue
- Proceedings of 2014 11th International Bhurban Conference on Applied Sciences & Technology (IBCAST) Islamabad, Pakistan, 14th - 18th January, 2014
- Publisher
- IEEE
- Published
- 2014-01
- Pages
- 499-503
- OpenAlex
- W2076720940
- Cited by
- 90
- References
- 0
- FWCI
- 10.16
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CoAP-based healthcare sensor networks: A survey. https://app.cochat.ai/papers/10.1109/ibcast.2014.6778196
- The paper
- Khattak, H. A., Ruta, M., & Eugenio Di Sciascio, E. (2014). CoAP-based healthcare sensor networks: A survey. Proceedings of 2014 11th International Bhurban Conference on Applied Sciences & Technology (IBCAST) Islamabad, Pakistan, 14th - 18th January, 2014. https://doi.org/10.1109/ibcast.2014.6778196
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.