Three-phase load flow analysis of the unbalanced distribution networks
Abstract
This paper summarizes the results of a three-phase load flow analysis case study. This work was part of an overall energy systems modeling and analysis effort designed to develop a validated power flow study that facilitates understanding of power flow concepts for the present distribution networks operating in asymmetry conditions. To simplify data collection requirements and illustrate key concepts, a representative HV power distribution network with unbalanced loads was chosen for the study. The analysis methodology used in this illustrative case study and the lessons learned from the study could assist the grid operator in conducting power flow studies of operational areas of interest.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Even without installed PVs, battery storages and EV chargers, the existing situation with mostly single-phase household loads results in voltage unbalance that exceeds standard limits.
“Since the most of the household have single-phase loads, even the existing situation, without installed PVs, battery storages and EV chargers, results in voltage unbalance that exceeds the standard limits [25].”
From A Comprehensive Analysis of the Voltage Unbalance Factor in PV and EV Rich Non-Synthetic Low Voltage Distribution Networks (2020) · cites this paper as [25]
Cited by
Sorted by citations
Antić, T., Capuder, T., & Bolfek, M. (2020) · Energies · doi:10.3390/en14010117 · Cited by 51 · see citing works
“Since the most of the household have single-phase loads, even the existing situation, without installed PVs, battery storages and EV chargers, results in voltage unbalance that exceeds the standard limits [25].”
BackgroundPetridis, S., Blanas, O., Rakopoulos, D., Stergiopoulos, F., Nikolopoulos, N., & Voutetakis, S. (2021) · Energies · doi:10.3390/en14040897 · Cited by 38 · see citing works
- Authors
- Rusinaru, D., Manescu, L. G., Ciontu, M., & Alba, M.
- Affiliations
- University of Craiova (RO)
- ORCID
- Rusinaru, Denisa
- Venue
- 2016 International Conference on Applied and Theoretical Electricity (ICATE)
- Publisher
- IEEE
- Published
- 2016-10
- Pages
- 1-5
- OpenAlex
- W2553969488
- Cited by
- 8
- References
- 0
- Citations by year
- 2025: 1 · 2023: 3 · 2021: 1 · 2020: 1 · 2018: 1 · 2017: 1
- FWCI
- 0.94
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Applied and Theoretical Electricity (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Keywords
- three-phase load flow, unbalanced distribution systems, power flow analysis, unbalanced loads, grid operators, power distribution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review