CoChat

Impact of high PV penetration on voltage regulation in electrical distribution systems

Ari, G.K., Baghzouz, Y. · 2011 · 2011 International Conference on Clean Electrical Power (ICCEP)
Cited by 115

The DOI matches its Crossref record.

Abstract

Cloud-induced transients induced in photovoltaic (PV) power are considered as a potential barrier to further expansion when the penetration of this renewable generation resource reaches a high level in distribution systems. Such transients can cause voltage flicker or excessive operation of the voltage regulating equipment. This article studies these effects on part of a local distribution substation. Actual transformer load and solar irradiance data based on 1-minute interval are used to simulate the impact of 20% PV penetration on the feeder voltage during a time period that covers both clear and cloudy skies. Based on some specified conditions, the simulations indicate that voltage flicker is not a concern, but the tap changer operates excessively even when using a 5-minute time delay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iccep.2011.6036386

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 115

Metadata

Authors
Ari, G. K., & Baghzouz, Y.
Venue
2011 International Conference on Clean Electrical Power (ICCEP)
Publisher
IEEE
Published
2011-06
Pages
744-748
OpenAlex
W2037456577
Cited by
115
References
0
FWCI
8.26
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of high PV penetration on voltage regulation in electrical distribution systems. https://app.cochat.ai/papers/10.1109/iccep.2011.6036386
The paper
Ari, G. K., & Baghzouz, Y. (2011). Impact of high PV penetration on voltage regulation in electrical distribution systems. 2011 International Conference on Clean Electrical Power (ICCEP). https://doi.org/10.1109/iccep.2011.6036386

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.