Requirements and current solutions of wireless communication in industrial automation
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The industrial wireless automation sector exhibits a huge market growth in the last years. Today, many applications already use wireless technologies. However, the existing wireless solutions do not yet offer sufficient performance with respect to real-time and reliability requirements, particularly for closed-loop control applications. As a result, low latency wireless communication technologies will bridge the gap and can become a key factor for the wide-spread penetration of wireless in industrial communication systems. It is therefore the main goal of this paper to provide a comprehensive overview on requirements, current solutions, and challenges as well as opportunities for future wireless industrial systems. Thereby, presented requirement figures, analysis results, and performance evaluations are based on numerous practical examples from industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Linear diversity combining techniques
Brennan, D. G. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2002.808163 · Cited by 817
The Evolution of Factory and Building Automation
Sauter, T., Soucek, S., Kästner, W., & Dietrich, D. (2011) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2011.942175 · Cited by 149 · cited 2×
“Initially wireless systems are used almost only in monitoring and open-loop control applications at all different layers of the automation pyramid [1].”
BackgroundCena, G., Seno, L., Valenzano, A., & Zunino, C. (2010) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2010.2052058 · Cited by 136 · cited 1×
“[25], [26] [27] WISA [3], [28]”
Scheible, G., Dzung, D., Endresen, J., & Frey, J.-E. (2007) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2007.901481 · Cited by 115 · cited 2×
“…component providers of industrial wireless communication systems in the factory automation use typically existing WLAN and Bluetooth conform standard transceiver components and partly add proprietary protocol extensions, e.g. the IWLAN system of Siemens [2] and the WISA system of ABB [3].”
BackgroundMethodIntegration of a Wireless I/O Interface for PROFIBUS and PROFINET for Factory Automation
Kjellsson, J., Vallestad, A. E., Steigmann, R., & Dzung, D. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017098 · Cited by 88 · cited 1×
“[25], [26] [27] WISA [3], [28]”
Radio Channel Quality in Industrial Wireless Sensor Networks
Sexton, D., Mahony, M., Lapinski, M., & Werb, J. (2005) · ISA/IEEE Sensors for Industry Conference (SIcon) · doi:10.1109/sicon.2005.257875 · Cited by 73 · cited 1×
“The coexistence of several spatial dense located wireless systems using the same frequency band will introduce interference and can lead to decreased quality of service (QoS) and severe packet loss [19], [20].”
BackgroundTowards a reliable parallel redundant WLAN black channel
Rentschler, M., & Laukemann, P. (2012) · IEEE International Workshop on Factory Communication Systems (WFCS) · doi:10.1109/wfcs.2012.6242573 · Cited by 62 · cited 3×
“Since standard wired or wireless data transmission channels cannot be developed according to safety regulation procedures of IEC 61508, the so-called black-channel principle [17] must be utilized.”
BackgroundMethodSelf-citationSynchronize Your Watches: Part II: Special-Purpose Solutions for Distributed Real-Time Control
Cena, G., Bertolotti, I. C., Scanzio, S., Valenzano, A., & Zunino, C. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2248431 · Cited by 35 · cited 1×
“For that purpose, state of the art fieldbus systems incorporate dedicated synchronization mechanisms [14] to bound the instantaneous jitter T j;n of slave n ’s valid time estimate ˆ T v;n to an application specific threshold J In this context, the property of a communication system to provide…”
Background
Cited by
Schulz, P., Matthe, M., Klessig, H., Simsek, M., Fettweis, G., Ansari, J., Ashraf, S. A., Almeroth, B., Voigt, J., Riedel, I., et al. (2017) · IEEE Communications Magazine · doi:10.1109/mcom.2017.1600435cm · Cited by 815
Self-citationA Survey on Industrial Internet of Things: A Cyber-Physical Systems Perspective
Xu, H., Yu, W., Griffith, D., & Golmie, N. (2018) · IEEE Access · doi:10.1109/access.2018.2884906 · Cited by 637
Network Slicing to Enable Scalability and Flexibility in 5G Mobile Networks
Rost, P., Mannweiler, C., Michalopoulos, D. S., Sartori, C., Sciancalepore, V., Sastry, N., Holland, O., Tayade, S., Han, B., Bega, D., et al. (2017) · IEEE Communications Magazine · doi:10.1109/mcom.2017.1600920 · Cited by 529
URLLC and eMBB in 5G Industrial IoT: A Survey
Khan, B. S., Jangsher, S., Ahmed, A., & Al-Dweik, A. (2022) · IEEE Open Journal of the Communications Society · doi:10.1109/ojcoms.2022.3189013 · Cited by 216
Comparative Examination on Architecture and Protocol of Industrial Wireless Sensor Network Standards
Wang, Q., & Jiang, J. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2548360 · Cited by 182
“4 ms by combining TDMA and frequency hopping [36].”
Method
Metadata
- Authors
- Frotzscher, A., Wetzker, U., Bauer, M., Rentschler, M., Beyer, M., Elspass, S., & Klessig, H.
- Venue
- 2014 IEEE International Conference on Communications Workshops (ICC)
- Publisher
- IEEE
- Published
- 2014-06
- Pages
- 67-72
- ISSN
- 2164-7038 (ISSN-L)
- OpenAlex
- W2021268118
- Cited by
- 175
- References
- 8
- FWCI
- 31.48
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.