Nocturnal Cough and Snore Detection in Noisy Environments Using Smartphone-Microphones
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The reporting on nocturnal sounds like cough and snore is not only relevant to follow the progress of respiratory diseases of patients but also to assess the quality of sleep of subjects. In this study, we discuss an audio analysis approach to count individual cough events and the duration of snore sounds in presence of air-conditioner noise through recordings of a smartphone and computationally efficient classifiers. A new audio data set of cough and snore sounds was acquired from 26 subjects. Energy threshold-based segmentation was applied to identify cough or snore events in the original low noise dataset. A k-nearest neighbor classifier was trained to merge cough phases belonging to the same cough event, to derive the proper ground-truth labeling. The original audio signal was augmented by the superposition of air-conditioner noise, with a signal-to-noise ratio of -40dB to 40dB, to enrich the training set of the binary classifier. Nine out of 40 mel-frequency cepstral coefficients in combination with the logarithm of energy from an entire cough or snore event were computed. Various classifiers, such as k-nearest neighbor (k-NN), rule-based classifier, decision tree, random forest, naive Bayes, and support vector machine were benchmarked against each other. The k-NN classifier with k=1 resulted in the highest F1scores of.85 and.88 in the binary classification task using generalized and personalized models, respectively, considering noise augmented samples. These results underline the potential of smartphones to objectively report on patient symptoms through audio recordings at night.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davis, S., & Mermelstein, P. (1980) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1980.1163420 · Cited by 5,465
iSleep: unobtrusive sleep quality monitoring using smartphones
Hao, T., Xing, G., & Zhou, G. (2013) · Proceedings of the 11th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/2517351.2517359 · Cited by 216 · cited 1×
“explored the classification accuracy of sounds like cough and snore considering the microphone characteristics of various smartphones [11].”
Background
Cited by
COVID-19 cough classification using machine learning and global smartphone recordings
Pahar, M., Klopper, M., Warren, R., & Niesler, T. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104572 · Cited by 290
Maghded, H. S., Ghafoor, K. Z., Sadiq, A. S., Curran, K., Rawat, D. B., & Rabie, K. (2020) · 2020 IEEE 21st International Conference on Information Reuse and Integration for Data Science (IRI) · doi:10.1109/iri49571.2020.00033 · Cited by 279
Novel Coronavirus Cough Database: NoCoCoDa
Cohen-McFarlane, M., Goubran, R., & Knoefel, F. (2020) · IEEE Access · doi:10.1109/access.2020.3018028 · Cited by 78
Metadata
- Authors
- Vhaduri, S., Kessel, T. V., Ko, B., Wood, D., Wang, S., & Brunschwiler, T.
- Venue
- 2019 IEEE International Conference on Healthcare Informatics (ICHI)
- Publisher
- IEEE
- Published
- 2019-06
- Pages
- 1-7
- OpenAlex
- W2990878527
- Cited by
- 62
- References
- 2
- FWCI
- 59.49
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nocturnal Cough and Snore Detection in Noisy Environments Using Smartphone-Microphones. https://app.cochat.ai/papers/10.1109/ichi.2019.8904563
- The paper
- Vhaduri, S., Kessel, T. V., Ko, B., Wood, D., Wang, S., & Brunschwiler, T. (2019). Nocturnal Cough and Snore Detection in Noisy Environments Using Smartphone-Microphones. 2019 IEEE International Conference on Healthcare Informatics (ICHI). https://doi.org/10.1109/ichi.2019.8904563
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.