The DOI matches its Crossref record.
Integration of distributed generation in the power system - a power quality approach
Abstract
This paper gives an overview of the design and operation issues in distribution and transmission systems due to the integration of distributed generation. The hosting-capacity approach has been developed to obtain a quantitative measure on the amount of generation that can be connected without impairing the performance of the system. The hosting-capacity approach requires a set of well-defined performance indices together with acceptable limits.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The first official definition of HC available in the literature is the highest amount of distributed generation that can be integrated into a power system without the performance limit being violated.
“This development brought the first official definition of HC available in the literature as the highest amount of distributed generation that can be integrated into a power system without the performance limit being violated [18].”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [18]
The theoretical application of the concept developed in [18] is now the widely adopted methodology by network operators, regulators, and researchers to determine HC.
“The theoretical application of the concept developed in [18], is now the widely adopted methodology by network operators, regulators, and researchers to determine HC.”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [18]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- 10.1049/PBPO031E · DOI
- dugan, 2002, Electric Power Systems Quality
- ha?ger, 2006, the impact of distributed generation on distribution-system protection, Nordic Distribution Automation Conference
- bollen, 2000, Understanding power quality voltage dips and interruptions
- bollen, 2007, distributed generation and waveform distortion, Int Conf on Electricity Distribution (CIRED)
- 10.1109/PTC.2003.1304365 · DOI
- deuse, 2006, Interactions of Dispersed Energy Resources with power system in normal and emergency conditions
- bollen, 2005, Power quality Interaction between distributed generation the grid and other customers Electric Power Quality and Utilisation Magazine, 1
- 10.1109/TPWRD.2008.919180 · DOI
- bollen, 2006, the hosting capacity of distribution networks against high-frequency harmonics emitted by distributed generation, Proc Int Conf Harmonics and Quality of Power (ICHQP)
- deuse, 2007, effective impact of dg on distribution system protection, Int Conf on Electricity Distribution (CIRED)
- bollen, 2006, impact of increasing amounts of wind power on the dip frequency in transmission systems, Nordic Wind Power Conference
Cited by
Sorted by citations
Multiagent-Based Distribution Automation Solution for Self-Healing Grids
Eriksson, M., Armendariz, M., Vasilenko, O. O., Saleem, A., & Nordström, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2387098 · Cited by 149
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71
Metadata
- Authors
- Bollen, M. H. J., Yang, Y., & Hassan, F.
- Affiliations
- Luleå University of Technology (SE)
- Venue
- 2008 13th International Conference on Harmonics and Quality of Power
- Publisher
- IEEE
- Published
- 2008-09
- Pages
- 1-8
- OpenAlex
- W2105101238
- Cited by
- 82
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 6 · 2023: 7 · 2022: 4 · 2021: 6 · 2020: 5 · 2019: 5 · 2018: 7 · 2017: 3 · 2016: 3 · 2015: 6 · 2014: 9 · 2013: 4 · 2012: 5
- FWCI
- 4.74
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Harmonics and Quality of Power (publishedVersion)
- Funders
- Chalmers Tekniska Högskola
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- distributed generation, power quality, hosting capacity, distribution systems, transmission systems, performance index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review