Iterative multi-scale registration without landmarks
The DOI matches its Crossref record.
Abstract
We present an automatic sub-pixel registration algorithm that minimizes the mean square difference of intensities between a reference and a test data set (volumes or images). It uses spline processing, is based on a coarse-to-fine pyramid strategy, and performs minimization according to a variation of the iterative Marquardt-Levenberg (1963) scheme. The geometric deformation model is a general affine transformation that one may optionally restrict to a rigid-body (isometric scale, rotation and translation), procrustean (rotation and translation) or translational case; it also includes an optional parameter for the linear adaptation of intensity. We present several PET and fMRI experiments and show that this algorithm provides excellent results. We conclude that the multi-resolution refinement strategy is faster and more robust than a comparable single-scale one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
A review of wavelets in biomedical applications
Unser, M., & Aldroubi, A. (1996) · Proceedings of the IEEE · doi:10.1109/5.488704 · Cited by 754
Self-citationShmueli, K., van Gelderen, P., de Zwart, J. A., Horovitz, S. G., Fukunaga, M., Jansma, J. M., & Duyn, J. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.037 · Cited by 541
The relative metabolic demand of inhibition and excitation
Waldvogel, D., van Gelderen, P., Muellbacher, W., Ziemann, U., Immisch, I., & Hallett, M. (2000) · Nature · doi:10.1038/35023171 · Cited by 272
On the possibility of automatic multisensor image registration
Inglada, J., & Giros, A. (2004) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2004.835294 · Cited by 215
“1) Measures Using the Radiometry Values and the Probabilities: Within this class, we will not take into account the measures that are based on the differences of radiometries ( norm of the difference) [20]–[22] or textural measures, since they give low-quality results.”
BackgroundTrus, B. L., Roden, R. B. S., Greenstone, H. L., Vrhel, M., Schiller, J. T., & Booy, F. P. (1997) · Nature Structural & Molecular Biology · doi:10.1038/nsb0597-413 · Cited by 195
Yang, Y., Gu, H., Zhan, W., Xu, S., Silbersweig, D. A., & Stern, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10196 · Cited by 77
“To minimize head motion artifacts, the time series of 3D brain volumes was registered using a multiresolution least-squares difference algorithm with cubic spline interpolation (37,38).”
Method
Metadata
- Authors
- Thevenaz, P., Ruttimann, U. E., & Unser, M.
- Venue
- Proceedings., International Conference on Image Processing
- Publisher
- IEEE Comput. Soc. Press
- Published
- 2002-11-19
- Volume
- 3
- Pages
- 228-231
- ISSN
- 1522-4880 (ISSN-L)
- OpenAlex
- W2151961258
- Cited by
- 63
- References
- 0
- FWCI
- 3.22
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.