The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ARMin - Exoskeleton for Arm Therapy in Stroke Patients
Abstract
Task-oriented repetitive movement can improve movement performance in patients with neurological lesions. The application of robotics can serve to assist, enhance, evaluate and document rehabilitation of movements. ARMin is a robot for arm therapy applicable to the arm training in clinics. It has an exoskeleton structure and is equipped with position and force sensors. Our latest version ARMin II has six degrees of freedom. The mechanical structure, the actuators, and the sensors of the robot are optimized for patient-cooperative control strategies based on impedance and admittance architectures. The device can work in three therapy modes: passive mobilization, game therapy, and task-oriented training. This paper presents the technical components of the new version ARMin II, the therapy modes, the control strategy for a new example of a game therapy, and clinical results of a pilot study with 11 chronic stroke patients and of single case studies conducted with three chronic stroke patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277
Cited by
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
Self-citationTimmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Advances in upper limb stroke rehabilitation: a technology push
Loureiro, R. C. V., Harwin, W. S., Nagai, K., & Johnson, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0797-0 · Cited by 252
Metadata
- Authors
- Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R.
- Venue
- 2007 IEEE 10th International Conference on Rehabilitation Robotics
- Publisher
- IEEE
- Published
- 2007-06
- Pages
- 68-74
- ISSN
- 1945-7898 (ISSN-L)
- OpenAlex
- W2088806978
- Cited by
- 192
- References
- 1
- FWCI
- 17.73
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ARMin - Exoskeleton for Arm Therapy in Stroke Patients. https://app.cochat.ai/papers/10.1109/icorr.2007.4428408
- The paper
- Nef, T., Mihelj, M., Kiefer, G., Perndl, C., Muller, R., & Riener, R. (2007). ARMin - Exoskeleton for Arm Therapy in Stroke Patients. 2007 IEEE 10th International Conference on Rehabilitation Robotics. https://doi.org/10.1109/icorr.2007.4428408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.