A lightweight soft exosuit for gait assistance

Wehner, Michael, Quinlivan, Brendan, Aubin, Patrick M, Martinez-Villalpando, Ernesto, Baumann, Michael, Stirling, Leia, Holt, Kenneth, Wood, Robert +1 more·2013·2013 IEEE International Conference on Robotics and Automation

Abstract

In this paper we present a soft lower-extremity robotic exosuit intended to augment normal muscle function in healthy individuals. Compared to previous exoskeletons, the device is ultra-lightweight, resulting in low mechanical impedance and inertia. The exosuit has custom McKibben style pneumatic actuators that can assist the hip, knee and ankle. The actuators attach to the exosuit through a network of soft, inextensible webbing triangulated to attachment points utilizing a novel approach we call the virtual anchor technique. This approach is designed to transfer forces to locations on the body that can best accept load. Pneumatic actuation was chosen for this initial prototype because the McKibben actuators are soft and can be easily driven by an off-board compressor. The exosuit itself (human interface and actuators) had a mass of 3500 g and with peripherals (excluding air supply) is 7144 g. In order to examine the exosuit's performance, a pilot study with one subject was performed which investigated the effect of the ankle plantar-flexion timing on the wearer's hip, knee and ankle joint kinematics and metabolic power when walking. Wearing the suit in a passive unpowered mode had little effect on hip, knee and ankle joint kinematics as compared to baseline walking when not wearing the suit. Engaging the actuators at the ankles at 30% of the gait cycle for 250 ms altered joint kinematics the least and also minimized metabolic power. The subject's average metabolic power was 386.7 W, almost identical to the average power when wearing no suit (381.8 W), and substantially less than walking with the unpowered suit (430.6 W). This preliminary work demonstrates that the exosuit can comfortably transmit joint torques to the user while not restricting mobility and that with further optimization, has the potential to reduce the wearer's metabolic cost during walking.

Integrity signals

Registry

Crossref · 10.1109/icra.2013.6631046

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A soft lower extremity robotic exosuit was developed by Wehner et al at Harvard University to augment normal muscle function in healthy individuals.

    “a soft lower extremity robotic exosuit was developed by Wehner et al [48] at Harvard University (Cambridge, MA, USA) to augment normal muscle function in healthy individuals”

The citation lists haven’t been fetched yet

References 30 · Cited by 361

Authors
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C.
Affiliations
Harvard University (US)
Venue
2013 IEEE International Conference on Robotics and Automation
Publisher
IEEE
Published
2013-05
Pages
3362-3369
ISSN
1050-4729 (ISSN-L)
OpenAlex
W2055823008
Cited by
361
References
30
Citations by year
2026: 13 · 2025: 29 · 2024: 32 · 2023: 31 · 2022: 30 · 2021: 33 · 2020: 40 · 2019: 35 · 2018: 30 · 2017: 31 · 2016: 27 · 2015: 15 · 2014: 13
FWCI
36.35
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
soft exosuit, lower limb exoskeleton, gait assistance, McKibben pneumatic actuator, joint kinematics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review