A lightweight soft exosuit for gait assistance
Abstract
In this paper we present a soft lower-extremity robotic exosuit intended to augment normal muscle function in healthy individuals. Compared to previous exoskeletons, the device is ultra-lightweight, resulting in low mechanical impedance and inertia. The exosuit has custom McKibben style pneumatic actuators that can assist the hip, knee and ankle. The actuators attach to the exosuit through a network of soft, inextensible webbing triangulated to attachment points utilizing a novel approach we call the virtual anchor technique. This approach is designed to transfer forces to locations on the body that can best accept load. Pneumatic actuation was chosen for this initial prototype because the McKibben actuators are soft and can be easily driven by an off-board compressor. The exosuit itself (human interface and actuators) had a mass of 3500 g and with peripherals (excluding air supply) is 7144 g. In order to examine the exosuit's performance, a pilot study with one subject was performed which investigated the effect of the ankle plantar-flexion timing on the wearer's hip, knee and ankle joint kinematics and metabolic power when walking. Wearing the suit in a passive unpowered mode had little effect on hip, knee and ankle joint kinematics as compared to baseline walking when not wearing the suit. Engaging the actuators at the ankles at 30% of the gait cycle for 250 ms altered joint kinematics the least and also minimized metabolic power. The subject's average metabolic power was 386.7 W, almost identical to the average power when wearing no suit (381.8 W), and substantially less than walking with the unpowered suit (430.6 W). This preliminary work demonstrates that the exosuit can comfortably transmit joint torques to the user while not restricting mobility and that with further optimization, has the potential to reduce the wearer's metabolic cost during walking.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A soft lower extremity robotic exosuit was developed by Wehner et al at Harvard University to augment normal muscle function in healthy individuals.
“a soft lower extremity robotic exosuit was developed by Wehner et al [48] at Harvard University (Cambridge, MA, USA) to augment normal muscle function in healthy individuals”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [48]
The citation lists haven’t been fetched yet
References 30 · Cited by 361
- Authors
- Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C.
- Affiliations
- Harvard University (US)
- ORCID
- Venue
- 2013 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2013-05
- Pages
- 3362-3369
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2055823008
- Cited by
- 361
- References
- 30
- Citations by year
- 2026: 13 · 2025: 29 · 2024: 32 · 2023: 31 · 2022: 30 · 2021: 33 · 2020: 40 · 2019: 35 · 2018: 30 · 2017: 31 · 2016: 27 · 2015: 15 · 2014: 13
- FWCI
- 36.35
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- soft exosuit, lower limb exoskeleton, gait assistance, McKibben pneumatic actuator, joint kinematics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review