The DOI matches its Crossref record.
Accelerometer Placement for Posture Recognition and Fall Detection
Abstract
This paper presents an approach to fall detection with accelerometers that exploits posture recognition to identify postures that may be the result of a fall. Posture recognition as a standalone task was also studied. Nine placements of up to four sensors were considered: on the waist, chest, thigh and ankle. The results are compared to the results of a system using ultra wide band location sensors on a scenario consisting of events difficult to recognize as falls or non-falls. Three accelerometers proved sufficient to correctly recognize all the events except one(a slow fall). The location-based system was comparable to two accelerometers, except that it was able to recognize the slow fall because it resulted in lying outside the bed, whose location was known to the system. One accelerometer was able to recognize only the most clear-cut fall. Two accelerometers achieved over 90% accuracy of posture recognition, which was better than the location-based system. Chest and waist accelerometers proved best at both tasks, with the chest accelerometer having a slight advantage in posture recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
Optimal Placement of Accelerometers for the Detection of Everyday Activities
Cleland, I., Kikhia, B., Nugent, C., Boytsov, A., Hallberg, J., Synnes, K., McClean, S., & Finlay, D. (2013) · Sensors · doi:10.3390/s130709183 · Cited by 401
A smartphone-based fall detection system
Abbate, S., Avvenuti, M., Bonatesta, F., Cola, G., Corsini, P., & Vecchio, A. (2012) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2012.08.003 · Cited by 357
Monitoring stress with a wrist device using context
Gjoreski, M., Luštrek, M., Gams, M., & Gjoreski, H. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.08.006 · Cited by 352
Self-citationMonitoring Activities of Daily Living in Smart Homes: Understanding human behavior
Debes, C., Merentitis, A., Sukhanov, S., Niessen, M., Frangiadakis, N., & Bauer, A. (2016) · IEEE Signal Processing Magazine · doi:10.1109/msp.2015.2503881 · Cited by 301
Metadata
- Authors
- Gjoreski, H., Lustrek, M., & Gams, M.
- Venue
- 2011 Seventh International Conference on Intelligent Environments
- Publisher
- IEEE
- Published
- 2011-07
- Pages
- 47-54
- OpenAlex
- W2163660327
- Cited by
- 207
- References
- 0
- FWCI
- 7.65
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerometer Placement for Posture Recognition and Fall Detection. https://app.cochat.ai/papers/10.1109/ie.2011.11
- The paper
- Gjoreski, H., Lustrek, M., & Gams, M. (2011). Accelerometer Placement for Posture Recognition and Fall Detection. 2011 Seventh International Conference on Intelligent Environments. https://doi.org/10.1109/ie.2011.11
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.