Design of an electronic power transformer
The DOI matches its Crossref record.
Abstract
For the distribution of electrical energy in Germany, application-specific transformers with ratings of 110/20 kV, 110/10kV, 40 MVA, 50 Hz are typically in operation. Due to their weight, these transformers can only be transported with great expense (usually by rail). Therefore a considerable number of reserve transformers has to be held in stock in each distribution area, to guarantee power reliability to utility customers by quick replacement. To reduce assets, a universal, mobile and flexible (adjustable to different medium-voltage levels and truck movable) transformer reserve unit is desired by utility companies. The modular design of an electronic power transformer for this purpose is given in this paper. Based on power electronics, additional features like fast voltage regulation, reactive power compensation, ride-through capability etc. are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applicability of solid-state transformers in today's and future distribution grids
Huber, J. E., & Kolar, J. W. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2738610 · Cited by 506
“Also, [15] has proposed SSTs as mobile (movable by truck) temporary replacements for large, heavy high-voltage to MV transformers.”
BackgroundAbu-Siada, A., Budiri, J., & Abdou, A. (2018) · Electronics · doi:10.3390/electronics7110298 · Cited by 69
Power Electronic Transformer application to grid connected photovoltaic systems
Brando, G., Dannier, A., & Rizzo, R. (2009) · 2009 International Conference on Clean Electrical Power · doi:10.1109/iccep.2009.5211954 · Cited by 31
“MV grid transforms voltages and currents from basic frequency of 50 Hz into a medium frequency MT. Different frequency converter schemes have been presented and discussed in literature relating to realization in distribution grid application with modern power electronic devices such as i.e.: three-phase to three-phase…”
BackgroundDetails and implementation of a SiC-based solid state transformer prototype
Ramirez, J. M., Barrios, R. A., & Salome, B. J. (2017) · 2017 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la.2017.8126690 · Cited by 6
“converter stage [9]; (iv) researchers at ETH Zurich are working on a matrix converter [6]; (v) the FREEDM project”
Background
Metadata
- Authors
- Wrede, H., Staudt, V., & Steimel, A.
- Venue
- IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02
- Publisher
- IEEE
- Published
- 2003-10-01
- Volume
- 2
- Pages
- 1380-1385
- OpenAlex
- W2537327328
- Cited by
- 35
- References
- 0
- FWCI
- 1.30
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of an electronic power transformer. https://app.cochat.ai/papers/10.1109/iecon.2002.1185477
- The paper
- Wrede, H., Staudt, V., & Steimel, A. (2003). Design of an electronic power transformer. IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02. https://doi.org/10.1109/iecon.2002.1185477
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.