The DOI matches its Crossref record.
IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces--Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III
Abstract
The performance and functional capability requirements for DER connected with the Area Electric Power Systems (Area EPS) are defined in IEEE Std 1547(TM). This amendment revises the ranges of allowable trip clearing time settings in Table 13 for DERs in abnormal operating performance category III to allow wider ranges that can broaden and simplify the adoption of the standard. In addition, the related informative Figure H.9 is revised accordingly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dutta, S., & Bauman, J. (2024) · IEEE Access · doi:10.1109/access.2024.3435463 · Cited by 37
Ferst, M. K., Weber Denardin, G., Marcelo de Oliveira Stein, C., Giovani Carati, E., Patric da Costa, J., & Cardoso, R. (2025) · IEEE Access · doi:10.1109/access.2025.3577972 · Cited by 5
Metadata
- Publisher
- IEEE
- Published
- 2020-03-09
- OpenAlex
- W4256422713
- Cited by
- 357
- References
- 0
- Type
- standard
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces--Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III. https://app.cochat.ai/papers/10.1109/ieeestd.2020.9069495
- The paper
- IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces--Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III. (2020). https://doi.org/10.1109/ieeestd.2020.9069495
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.