Performance Analysis of an Open Cycle Gas Turbine Power Plant in Grid Electricity Generation
The DOI matches its Crossref record.
Abstract
In this study, there was a performance analysis of a working 30MW open cycle gas turbine power plant to get a general overview of role and performance of gas turbines in supply of grid electricity. The historical evaluation of the gas turbine power plant technology is presented with features and application of gas turbines in electricity generation. It was found that a significant amount of energy is lost with the exhaust gases, which are released to the atmosphere. The amount was up to 74.6%, which is wasteful, polluting and unsustainable. Analysis on possible conversion from the open cycle to combined cycle plant demonstrated that subject to practical limitations, specific fuel consumption reduces by 22% and power output increases by 11.69 MW, which is 38% increase from the Rankine cycle turbine. This will improve on specific fuel consumption, generate more revenue and contribute towards greenhouse emission mitigation through avoided use of fossil fuels for extra power generated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sustainable Energy Transition for Renewable and Low Carbon Grid Electricity Generation and Supply
Kabeyi, M. J. B., & Olanrewaju, O. A. (2022) · Frontiers in Energy Research · doi:10.3389/fenrg.2021.743114 · Cited by 1,177
“…at a pace lower than the resource reproduction or substitution and they do not pollute the environment with emissions that accumulate beyond the capacity of natural systems to absorb and assimilate them (Kabeyi, 2018b; Barasa Kabeyi, 2019b; Kabeyi and Oludolapo, 2020b; Kabeyi et al., 2020).”
BackgroundSelf-citationBiogas Production and Applications in the Sustainable Energy Transition
Kabeyi, M. J. B., & Olanrewaju, O. A. (2022) · Journal of Energy · doi:10.1155/2022/8750221 · Cited by 442
“In larger units, the exhaust gases can be used to operate a Rankine cycle steam turbine for extra power generation by generating steam using a waste heat recovery boiler [60].”
BackgroundMethodInfluentialSelf-citationSmart grid technologies and application in the sustainable energy transition: a review
Kabeyi, M. J. B., & Olanrewaju, O. A. (2023) · International Journal of Sustainable Energy · doi:10.1080/14786451.2023.2222298 · Cited by 183
Self-citationGeothermal wellhead technology power plants in grid electricity generation: A review
Barasa Kabeyi, M. J., & Olanrewaju, O. A. (2022) · Energy Strategy Reviews · doi:10.1016/j.esr.2021.100735 · Cited by 110
Self-citationPerformance Analysis and Evaluation of Muhoroni 60MW Gas Turbine Power Plant
Barasa Kabeyi, M. J., & Olanrewaju, O. A. (2021) · 2021 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · doi:10.1109/iceccme52200.2021.9591134 · Cited by 10
Self-citationConversion of a Flash Power Plant to Organic Rankine System for Olkaria Geothermal Power Plants
Barasa Kabeyi, M. J., & Olanrewaju, O. A. (2021) · 2021 International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · doi:10.1109/iceccme52200.2021.9591048 · Cited by 10
Self-citation
Metadata
- Authors
- Kabeyi, M. J. B., & Olanrewaju, O. A.
- Venue
- 2020 IEEE International Conference on Industrial Engineering and Engineering Management (IEEM)
- Publisher
- IEEE
- Published
- 2020-12-14
- Pages
- 524-529
- OpenAlex
- W3119262812
- Cited by
- 33
- References
- 0
- FWCI
- 15.74
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.