Low-cost active electrode improves the resolution in biopotential recordings
The DOI matches its Crossref record.
Abstract
The accepted models of the origin of interference in body surface potential recordings predict that it would be advantageous to perform signal amplification on the electrode. A suitable circuit for a miniature biopotential amplifier to be manufactured in thick-film technology is described. A prototype series of active electrodes was produced and tested. The high immunity to interference resulted in ECG and EEG recordings of a very high quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
“It can ensure that the recorded signal is insensitive to interference [21].”
BackgroundShort-term emotion assessment in a recall paradigm
Chanel, G., Kierkels, J. J. M., Soleymani, M., & Pun, T. (2009) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2009.03.005 · Cited by 367
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 288
The neurophysiological bases of EEG and EEG measurement: A review for the rest of us
Jackson, A. F., & Bolger, D. J. (2014) · Psychophysiology · doi:10.1111/psyp.12283 · Cited by 264
High and dry? Comparing active dry EEG electrodes to active and passive wet electrodes
Mathewson, K. E., Harrison, T. J. L., & Kizuk, S. A. D. (2017) · Psychophysiology · doi:10.1111/psyp.12536 · Cited by 211
Active Electrodes for Wearable EEG Acquisition: Review and Electronics Design Methodology
Xu, J., Mitra, S., Van Hoof, C., Yazicioglu, R. F., & Makinwa, K. A. A. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2656388 · Cited by 197
Impedance and Noise of Passive and Active Dry EEG Electrodes: A Review
Habibzadeh Tonekabony Shad, E., Molinas, M., & Ytterdal, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3012394 · Cited by 173
“Furthermore, a low output impedance amplifier helps to suppress cable artifacts and eliminate the need of using a shield for wires [45].”
BackgroundMethodological aspects of EEG and body dynamics measurements during motion
Reis, P. M. R., Hebenstreit, F., Gabsteiger, F., von Tscharner, V., & Lochmann, M. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00156 · Cited by 159
Wienberg, M., Glenthoj, B., Jensen, K., & Oranje, B. (2010) · Journal of Psychopharmacology · doi:10.1177/0269881109102606 · Cited by 68
Metadata
- Authors
- MettingVanRijn, A. C., Kuiper, A. P., Dankers, T. E., & Grimbergen, C. A.
- Venue
- Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2002-12-24
- Volume
- 1
- Pages
- 101-102
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2536390524
- Cited by
- 88
- References
- 0
- FWCI
- 9.87
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.