CoChat

A simplified superconducting quantum interference device system to analyze vector components of a cardiac magnetic field

Tsukada, K., Kandori, A., Miyashita, T., Sasabuti, H., Suzuki, H., Kondo, S., Komiyama, Y., Teshigawara, K. · 2002 · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)
Cited by 42

The DOI matches its Crossref record.

Abstract

We have developed a 64-channnel superconducting quantum interference (SQUID) system that can analyze the vector components of a cardiac magnetic field, and that is more compact and requires fewer SQUID sensors and measuring circuits than existing systems. To adjust the position of the dewar, containing sensor array and liquid He relative to the chest, the bed is capable of three-dimensional movement. The magneto-cardiogram (MCG) data from the 64 channels are stored and analyzed using a personal computer. Each measurement site contains first-order gradiometers to detect the Bz component on the torso. The typical noise of the system in a magnetically shielded room (MSR) is less than 20 fT//spl radic/Hz. Tangential components at each measuring site can be calculated from the first-order gradient of Bz in the x- and y-directions. Two types of magnetic-field patterns of the Bz component and the Bxy tangential components are obtained at the same time. The position and distribution of a current source in the heart can be visualized through a two-dimensional projection using the analyzed tangential magnetic field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.1998.745962

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 42

Metadata

Authors
Tsukada, K., Kandori, A., Miyashita, T., Sasabuti, H., Suzuki, H., Kondo, S., Komiyama, Y., & Teshigawara, K.
Venue
Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)
Publisher
IEEE
Published
2002-11-27
Pages
524-527
ISSN
2375-7477 (ISSN-L)
OpenAlex
W2165621729
Cited by
42
References
0
FWCI
6.77
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simplified superconducting quantum interference device system to analyze vector components of a cardiac magnetic field. https://app.cochat.ai/papers/10.1109/iembs.1998.745962
The paper
Tsukada, K., Kandori, A., Miyashita, T., Sasabuti, H., Suzuki, H., Kondo, S., Komiyama, Y., & Teshigawara, K. (2002). A simplified superconducting quantum interference device system to analyze vector components of a cardiac magnetic field. Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286). https://doi.org/10.1109/iembs.1998.745962

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.