A simplified superconducting quantum interference device system to analyze vector components of a cardiac magnetic field
The DOI matches its Crossref record.
Abstract
We have developed a 64-channnel superconducting quantum interference (SQUID) system that can analyze the vector components of a cardiac magnetic field, and that is more compact and requires fewer SQUID sensors and measuring circuits than existing systems. To adjust the position of the dewar, containing sensor array and liquid He relative to the chest, the bed is capable of three-dimensional movement. The magneto-cardiogram (MCG) data from the 64 channels are stored and analyzed using a personal computer. Each measurement site contains first-order gradiometers to detect the Bz component on the torso. The typical noise of the system in a magnetically shielded room (MSR) is less than 20 fT//spl radic/Hz. Tangential components at each measuring site can be calculated from the first-order gradient of Bz in the x- and y-directions. Two types of magnetic-field patterns of the Bz component and the Bxy tangential components are obtained at the same time. The position and distribution of a current source in the heart can be visualized through a two-dimensional projection using the analyzed tangential magnetic field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345263 · Cited by 45
Self-citationUltra-sensitive vector magnetometer for magnetocardiographic mapping
Gusev, N. A., Vetoshko, P. M., Kuzmichev, A. N., Chepurnova, D. A., Samoilova, E. V., Zvezdin, A. K., Korotaeva, A. A., & Belotelov, V. I. (2017) · Biomedical Engineering · doi:10.1007/s10527-017-9705-8 · Cited by 9
Metadata
- Authors
- Tsukada, K., Kandori, A., Miyashita, T., Sasabuti, H., Suzuki, H., Kondo, S., Komiyama, Y., & Teshigawara, K.
- Venue
- Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286)
- Publisher
- IEEE
- Published
- 2002-11-27
- Pages
- 524-527
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2165621729
- Cited by
- 42
- References
- 0
- FWCI
- 6.77
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simplified superconducting quantum interference device system to analyze vector components of a cardiac magnetic field. https://app.cochat.ai/papers/10.1109/iembs.1998.745962
- The paper
- Tsukada, K., Kandori, A., Miyashita, T., Sasabuti, H., Suzuki, H., Kondo, S., Komiyama, Y., & Teshigawara, K. (2002). A simplified superconducting quantum interference device system to analyze vector components of a cardiac magnetic field. Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286). https://doi.org/10.1109/iembs.1998.745962
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.