The DOI matches its Crossref record, with a small difference in title or year.
Driven gait orthosis to do locomotor training of paraplegic patients
Abstract
Recent studies have confirmed that with a regular treadmill training walking capabilities in incomplete spinal cord injured subjects as well as in hemiplegic patients can be improved. In the beginning of this training the legs of the patients have to be assisted. So far this has been done by physiotherapists guiding the legs during gait on a moving treadmill. As this can be a very exhausting job for the therapists, the training usually is too short to get optimal results. Therefore a driven gait orthosis has been developed that can move the legs of a patient in a physiological way on a moving treadmill. The orthosis is adjustable in size so different patients can use it. There are actuators at the knee and hip joints that are controlled via a position controller. A passive foot lifter controls the ankle joint. This setup allows the legs of the patient to be moved in different, physiological gait patterns on the treadmill without any assistance of the patient or a physiotherapist. First tests with the orthosis showed good results. Several patients could be trained for more then half an hour and with a higher speed then in the manually assisted training. All trained patients reported no problems with this training; on the contrary, they felt more comfortable with the new method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
To date, trajectory tracking control is primarily used in LEEs for early stage rehabilitation when patients have very weak muscle strength.
“To date, trajectory tracking control is primarily used in LEEs for early stage rehabilitation when patients have very weak muscle strength [58], [59].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [58]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 10
- 10.1111/j.1460-9568.1995.tb00686.x · DOI
- 10.1016/S0140-6736(94)90751-X · DOI
- ruthenberg, 1997, An experimental device for investigating the force and power requirements of a powered gait orthosis, Journal of Rehabilitation Research & Development, 34, 203
- 10.1038/sc.1971.31 · DOI
- 10.1038/sc.1992.61 · DOI
- miyamoto, 1985, Approach to a powered orthosis for paralyzed lower limbs, ICAR 85, 451
- seireg, 1981, Biomechanics of Medical Devices, 569
- 10.1002/ana.410370506 · DOI
- 10.1109/IROS.1990.262524 · DOI
- 10.1016/S0003-9993(99)90126-0 · DOI
Cited by
Sorted by citations
An Analysis of Usability Evaluation Practices and Contexts of Use in Wearable Robotics
Meyer, J. T., Gassert, R., & Lambercy, O. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00963-8 · Cited by 58
Metadata
- Authors
- Colombo, G., Jorg, M., & Dietz, V.
- Affiliations
- Universitätsklinik Balgrist (CH)
- ORCID
- Venue
- Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143)
- Publisher
- IEEE
- Published
- 2002-11-11
- Volume
- 4
- Pages
- 3159-3163
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2107500431
- Cited by
- 72
- References
- 0
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 5 · 2018: 3 · 2017: 3 · 2016: 3 · 2015: 2 · 2014: 4 · 2013: 2 · 2012: 7
- FWCI
- 1.79
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- locomotor training, paraplegia, incomplete spinal cord injury, treadmill training, position control, rehabilitation robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review