Line length: an efficient feature for seizure onset detection
The DOI matches its Crossref record.
Abstract
A signal feature with low computational burden is presented as an efficient tool for seizure onset detection. The feature was evaluated over a total of. 1,215 hours of intracranial EEG signal from 10 patients. Results confirmed this feature as being useful for seizure onset detection yielding an average delay of 4.1 seconds, 0.051 false positives per hour, and one false negative on a subclinical seizure out of 111 seizures analyzed of which 23 were subclinical.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paz, J. T., Davidson, T. J., Frechette, E. S., Delord, B., Parada, I., Peng, K., Deisseroth, K., & Huguenard, J. R. (2013) · Nature Neuroscience · doi:10.1038/nn.3269 · Cited by 566
Worrell, G. A., Gardner, A. B., Stead, S. M., Hu, S., Goerss, S., Cascino, G. J., Meyer, F. B., Marsh, R., & Litt, B. (2008) · Brain · doi:10.1093/brain/awn006 · Cited by 458
Self-citationMethods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
A review of epileptic seizure detection using machine learning classifiers
Siddiqui, M. K., Morales-Menendez, R., Huang, X., & Hussain, N. (2020) · Brain Informatics · doi:10.1186/s40708-020-00105-1 · Cited by 432
Guo, L., Rivero, D., Dorado, J., Rabuñal, J. R., & Pazos, A. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.020 · Cited by 430
A review of feature extraction and performance evaluation in epileptic seizure detection using EEG
Boonyakitanont, P., Lek-uthai, A., Chomtho, K., & Songsiri, J. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101702 · Cited by 390
A Novel Multi-Class EEG-Based Sleep Stage Classification System
Memar, P., & Faradji, F. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2776149 · Cited by 318
Responsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 309
Closed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Şen, B., Peker, M., Çavuşoğlu, A., & Çelebi, F. V. (2014) · Journal of Medical Systems · doi:10.1007/s10916-014-0018-0 · Cited by 282
Emerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
D'Alessandro, M., Esteller, R., Vachtsevanos, G., Hinson, A., Echauz, J., & Litt, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.810706 · Cited by 271
Self-citationOne-Class Novelty Detection for Seizure Analysis from Intracranial EEG
Gardner, A. B., Krieger, A. Μ., Vachtsevanos, G., & Litt, B. (2006) · doi:10.5555/1248547.1248584 · Cited by 270
Self-citationThe RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy
Sun, F. T., & Morrell, M. J. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.947274 · Cited by 266
Human and automated detection of high-frequency oscillations in clinical intracranial EEG recordings
Gardner, A. B., Worrell, G. A., Marsh, E., Dlugos, D., & Litt, B. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.12.019 · Cited by 264
Self-citationMachine-learning-based diagnostics of EEG pathology
Gemein, L. A. W., Schirrmeister, R. T., Chrabąszcz, P., Wilson, D., Boedecker, J., Schulze-Bonhage, A., Hutter, F., & Ball, T. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117021 · Cited by 218
A comparison of quantitative EEG features for neonatal seizure detection
Greene, B. R., Faul, S., Marnane, W. P., Lightbody, G., Korotchikova, I., & Boylan, G. B. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.02.001 · Cited by 217
Ictal high frequency oscillations distinguish two types of seizure territories in humans
Weiss, S. A., Banks, G. P., McKhann, G. M., Goodman, R. R., Emerson, R. G., Trevelyan, A. J., & Schevon, C. A. (2013) · Brain · doi:10.1093/brain/awt276 · Cited by 201
“Line length (Esteller et al., 2001) was calculated from filtered EEG (2–25 Hz, 500th order symmetric finite impulse response filter) and normalized to a 30 s pre-ictal baseline.”
Wulsin, D. F., Gupta, J. R., Mani, R., Blanco, J. A., & Litt, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036015 · Cited by 185
Self-citationZhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“, line-length [65], the Hjorth parameters of activity, mobility, and complexity [2], [63], [66], number of peaks, peak-to-peak amplitude and peak latency [63]), biomarkers that measure connectivity between different brain regions such as phase-amplitude coupling and phase locking value [2], [64], [67]–[69], and the co…”
BackgroundMulti-modality of polysomnography signals’ fusion for automatic sleep scoring
Yan, R., Zhang, C., Spruyt, K., Wei, L., Wang, Z., Tian, L., Li, X., Ristaniemi, T., Zhang, J., & Cong, F. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.10.001 · Cited by 49
Sun, J., Barth, K., Qiao, S., Chiang, C.-H., Wang, C., Rahimpour, S., Trumpis, M., Duraivel, S., Dubey, A., Wingel, K. E., et al. (2022) · Brain Communications · doi:10.1093/braincomms/fcac122 · Cited by 31
Metadata
- Authors
- Esteller, R., Echauz, J., Tcheng, T., Litt, B., & Pless, B.
- Venue
- 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-08-24
- Pages
- 1707-1710
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2143776609
- Cited by
- 250
- References
- 0
- FWCI
- 17.84
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.