Gait analysis for freezing detection in patients with movement disorder using three dimensional acceleration system
The DOI matches its Crossref record.
Abstract
Due to the aging process, the aftereffect of an accident or the problems in brain, some people can experience difficulties in walking. It could be helpful in the treatment of these individuals suffering walking difficulties to monitor their movement. The unconstrained activity monitoring system (U-AMS) was developed to monitor the body's acceleration. It can be attached easily and doesn't interfere with daily activity. The hardware consists of 3-axis accelerometer, which records data for long periods of time. The movement image was simultaneously recorded by a camcorder. To collect data from U-AMS and analyze them, several programs were developed. The data were transferred to a computer by RS-232 module and displayed through viewing program made by MFC (Microsoft, USA). The analyzing program, which links viewing program to MATLAB (Mathworks, USA), analyzes the data to detect movement disorder. In this paper, freezing, which is characterized as start hesitation., was the target disorder. Using the different characteristics in frequency domain between freezing and normal gait, freezing appearances were detected. By comparing with movement image, the accuracy of the freezing detection was verified to have a good performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171764 · Cited by 237
Online Detection of Freezing of Gait with Smartphones and Machine Learning Techniques
Mazilu, S., Hardegger, M., Zhu, Z., Roggen, D., Troester, G., Plotnik, M., & Hausdorff, J. (2012) · Proceedings of the 6th International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2012.248680 · Cited by 231
“Han and collegues [22] made a first attempt to detect FoG episodes in PD patients by monitoring body acceleration using a 3-axis accelerometer.”
MethodAshfaque Mostafa, T., Soltaninejad, S., McIsaac, T. L., & Cheng, I. (2021) · Sensors · doi:10.3390/s21196446 · Cited by 32
Gait Recovery System for Parkinson’s Disease using Machine Learning on Embedded Platforms
Gokul, H., Suresh, P., Hari Vignesh, B., Pravin Kumaar, R., & Vijayaraghavan, V. (2020) · 2020 IEEE International Systems Conference (SysCon) · doi:10.1109/syscon47679.2020.9275930 · Cited by 23
“Han et al [15], first attempted to tackle the gait freezing disorder using body worn accelerometers in their monitoring system with frequency domain analysis.”
Background
Metadata
- Authors
- Han, J. H., Lee, W. J., Ahn, T. B., Jeon, B. S., & Park, K. S.
- Venue
- Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439)
- Publisher
- IEEE
- Published
- 2004-06-21
- Pages
- 1863-1865
- OpenAlex
- W1585759200
- Cited by
- 44
- References
- 0
- FWCI
- 7.47
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gait analysis for freezing detection in patients with movement disorder using three dimensional acceleration system. https://app.cochat.ai/papers/10.1109/iembs.2003.1279781
- The paper
- Han, J. H., Lee, W. J., Ahn, T. B., Jeon, B. S., & Park, K. S. (2004). Gait analysis for freezing detection in patients with movement disorder using three dimensional acceleration system. Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439). https://doi.org/10.1109/iembs.2003.1279781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.