A low-power integrated circuit for adaptive detection of action potentials in noisy signals
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The advent of microelectrode arrays allowing for the simultaneous recording of 100 or more neurons is leading to significant advances in science and medicine. However, the amount of data generated by these arrays presents a technical challenge if these systems are ever to be fully implanted for neuroprosthetic applications. We have developed an algorithm to perform real-time data reduction by detecting action potentials, or "spikes," embedded in a noisy signal. This algorithm is simple enough to be implemented in a mixed-signal integrated circuit consuming less than 60 /spl mu/W of power. Experimental results from a chip show that the circuit is able to adaptively set a spike detection threshold above the background noise level of a signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Self-citation
Cited by
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Self-citationA Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
Self-citationThe Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330
“The goal of our spike-detection algorithm (first described in [ 41 ]) is to adaptively set a detection threshold that is low enough to capture action potentials but high enough to reject occasional peaks in the background noise.”
MethodSelf-citationCompressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2193668 · Cited by 311
A three-dimensional neural recording microsystem with implantable data compression circuitry
Olsson, R. H., & Wise, K. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.858479 · Cited by 245
“detection consumes slightly more power, 75μW/channel, than a previously reported analog technique [5], comparator offsets do not degrade detection.”
Background
Metadata
- Authors
- Harrison, R. R.
- Venue
- Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439)
- Publisher
- IEEE
- Published
- 2004-05-13
- Pages
- 3325-3328
- OpenAlex
- W1484704128
- Cited by
- 137
- References
- 1
- FWCI
- 13.08
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A low-power integrated circuit for adaptive detection of action potentials in noisy signals. https://app.cochat.ai/papers/10.1109/iembs.2003.1280856
- The paper
- Harrison, R. R. (2004). A low-power integrated circuit for adaptive detection of action potentials in noisy signals. Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439). https://doi.org/10.1109/iembs.2003.1280856
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.