The tremor coherence analyzer (TCA): a portable tool to assess instantaneous inter-muscle coupling in tremor
Abstract
This paper proposes a novel system for pathological tremor study and diagnosis. The system described called TCA (tremor coherence analyzer) is based on a electronic device developed for wireless monitoring of physiological variables. The device uses Bluetooth technology to communicate. The proposed technique for pathological tremor analysis uses surface EMG signals. The EMG sensors are located on forearm muscles to measure muscular activity due to pathological tremor. The coherence function between these signals is calculated. The application of the coherence function allows to determine linear dependencies between two signals.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wireless inertial sensors combining different types of sensors are now being applied.
“Wireless inertial sensor with the combination of different types of sensors (for instance three linear accelerometers, three gyroscopes and three magnetometers [61]) is now being applied.”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [61]
Cited by
Sorted by citations
Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Grimaldi, G., & Manto, M. (2010) · Sensors · doi:10.3390/s100201399 · Cited by 138 · see citing works
“Wireless inertial sensor with the combination of different types of sensors (for instance three linear accelerometers, three gyroscopes and three magnetometers [61]) is now being applied.”
MethodSelf-citation
- Authors
- Brunetti, F. J., Rocon, E., Pons, J. L., & Manto, M.
- Affiliations
- Consejo Superior de Investigaciones Científicas (ES)
- Université Libre de Bruxelles (BE)
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-03-21
- Volume
- 3
- Pages
- 61-64
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2153604960
- Cited by
- 6
- References
- 0
- FWCI
- 3.10
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Keywords
- pathological tremor, coherence function, surface electromyography, forearm muscles, tremor diagnosis, portable monitoring device
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review