Generalizing to new subjects in brain-computer interfacing
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper evaluates an algorithm based on support vector machines to analyze EEG data from the P300 speller brain-computer interface paradigm. We evaluated the performance of this technique on own experimental data from 8 subjects and achieved high transfer rates of up to 97.57 bits/min (mean 47.26 bits/min) within subjects. We then investigated how well the classifier generalizes when it is trained on data from a set of several subjects and then applied on data from a new subject to use this BCI in a pretrained fashion. Transfer rates up to 61.04 bits/min were achieved (mean 17.64 bits/min) for this situation indicating an encouraging generalization performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Therefore, by identifying this P300 component in the EEG pattern it is possible to infer the attended symbol [7, 8].”
Background
Cited by
Blankertz, B., Dornhege, G., Krauledat, M., Müller, K.-R., & Curio, G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.051 · Cited by 946
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
The Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
“Lately, a number of attempts have been made to overcome the calibration by means of specifically developed machine learning techniques, e.g., Kaper and Ritter (2004), Lu et al. (2009) for P300 and Allison et al. (2008), Cecotti (2010) for SSVEP as well as Krauledat et al. (2008) for SMR-based BCIs…”
Background
Metadata
- Authors
- Kaper, M., & Ritter, H.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-04-12
- Volume
- 4
- Pages
- 4363-4366
- OpenAlex
- W2167068610
- Cited by
- 38
- References
- 1
- FWCI
- 12.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generalizing to new subjects in brain-computer interfacing. https://app.cochat.ai/papers/10.1109/iembs.2004.1404214
- The paper
- Kaper, M., & Ritter, H. (2005). Generalizing to new subjects in brain-computer interfacing. The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2004.1404214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.