Adaptive filtering and alternative calculations revolutionizes pulse oximetry sensitivity and specificity during motion and low perfusion
The DOI matches its Crossref record.
Abstract
Pulse oximetry, utilizing spectrophotometric principles and normalized absorption of red and infrared light, provides vital information concerning patients' arterial oxygen saturation, pulse rate and perfusion level. Conventional pulse oximeters, incorporating conventional filters, are hampered by artifact interference from motion, electrical and ambient light and other conditions producing weak signals. Masimo introduced mathematically and physiologically based designs along with adaptive filtering and what it calls DST (Discrete Saturation Transform) as a solution to monitoring patients even during times of severe and unpredictable noise interference. This combined with 4 other alternative calculations, revolutionized pulse oximetry performance. This new technology is called Signal Extraction Pulse Oximetry or Masimo SET pulse oximetry. Sensitivity and specificity of signal extraction technology, was first tested extensively in the lab on volunteers under conditions designed to simulate varying physiology, including controlled desaturations, combined with severe patient motion, and low perfusion conditions. Conventional pulse oximeters demonstrated very low sensitivity and specificity while pulse oximeters with SET showed sensitivity and specificity of over 95% under the same conditions. Clinical testing was then performed on an extensive variety of patients in the hospital environment demonstrating similar performance, validating the significant advance resulting from the use of SET. False alarms due to motion artifact and low perfusion have been reduced from up to 90% to less than 5%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Li, Q., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1491 · Cited by 274
Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data
Krishnan, R., Natarajan, B., & Warren, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2039568 · Cited by 263
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
The Effect of Motion on Pulse Oximetry and Its Clinical Significance
Petterson, M. T., Begnoche, V. L., & Graybeal, J. M. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278134.47777.a5 · Cited by 176
“The DST algorithm was developed specifically to identify the arterial signal in the presence of the nonarterial (venous) signal that occurs during motion (22,23,38,39).”
MethodSelf-citationSignal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33
Metadata
- Authors
- Graybeal, J. M., & Petterson, M. T.
- Venue
- The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2005-03-21
- Volume
- 4
- Pages
- 5363-5366
- OpenAlex
- W2545853400
- Cited by
- 41
- References
- 0
- FWCI
- 3.88
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.