A WBAN System for Ambulatory Monitoring of Physical Activity and Health Status: Applications and Challenges
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Recent technological advances in sensors, low-power integrated circuits, and wireless communications have enabled the design of low-cost, miniature, lightweight, intelligent physiological sensor platforms that can be seamlessly integrated into a body area network for health monitoring. Wireless body area networks (WBANs) promise unobtrusive ambulatory health monitoring for extended periods of time and near real-time updates of patients' medical records through the Internet. A number of innovative systems for health monitoring have recently been proposed. However, they typically rely on custom communication protocols and hardware designs, lacking generality and flexibility. The lack of standard platforms, system software support, and standards makes these systems expensive. Bulky sensors, high price, and frequent battery changes are all likely to limit user compliance. To address some of these challenges, we prototyped a WBAN utilizing a common off-the-shelf wireless sensor platform with a ZigBee-compliant radio interface and an ultra low-power microcontroller. The standard platform interfaces to custom sensor boards that are equipped with accelerometers for motion monitoring and a bioamplifier for electrocardiogram or electromyogram monitoring. Software modules for on-board processing, communication, and network synchronization have been developed using the TinyOS operating system. Although the initial WBAN prototype targets ambulatory monitoring of user activity, the developed sensors can easily be adapted to monitor other physiological parameters. In this paper, we discuss initial results, implementation challenges, and the need for standardization in this dynamic and promising research field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jovanov, E., Milenkovic, A., Otto, C., & de Groen, P. C. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-6 · Cited by 1,013
Self-citationCodeBlue: An Ad Hoc Sensor Network Infrastructure for Emergency Medical Care
Malan, D. J., Fulford-Jones, T. R. F., Welsh, M., & Moulton, S. (2004) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 798
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766 · cited 1×
“I. INTRODUCTION Wireless body area networks (WBANs) signify emerging technology with the potential to revolutionize health care by allowing unobtrusive health monitoring for extended periods of time [1][2].”
BackgroundSelf-citationActivity and location recognition using wearable sensors
Lee, S.-W., & Mase, K. (2002) · IEEE Pervasive Computing · doi:10.1109/mprv.2002.1037719 · Cited by 525 · cited 1×
“Solutions range from inexpensive devices such as pedometers to complex implementations featuring several accelerometers and gyroscopes located on different characteristic points on the body (ankle, arm, waist, thigh, etc.) [3][4][5][6].”
BackgroundA Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221 · cited 1×
“Solutions range from inexpensive devices such as pedometers to complex implementations featuring several accelerometers and gyroscopes located on different characteristic points on the body (ankle, arm, waist, thigh, etc.) [3][4][5][6].”
BackgroundA 300-μm W 1.9-ghz cmos oscillator utilizing micromachined resonators
Otis, B. P., & Rabaey, J. M. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.813219 · Cited by 179 · cited 1×
“Several emerging technologies, such as extremely low power wireless MEMS transceivers [13], promise further performance improvements of 2-3 orders of magnitude.”
BackgroundSteele, B. G., Belza, B., Cain, K., Warms, C., Coppersmith, J., & Howard, J. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.10.0045 · Cited by 176 · cited 1×
“Monitoring physical activity has become increasingly important as many studies link physical activity with overall health status [3].”
BackgroundUnsupervised, dynamic identification of physiological and activity context in wearable computing
Krause, A., Siewiorek, D. P., Smailagic, A., & Farringdon, J. (2004) · Seventh IEEE International Symposium on Wearable Computers, 2003. Proceedings. · doi:10.1109/iswc.2003.1241398 · Cited by 153 · cited 1×
“Solutions range from inexpensive devices such as pedometers to complex implementations featuring several accelerometers and gyroscopes located on different characteristic points on the body (ankle, arm, waist, thigh, etc.) [3][4][5][6].”
BackgroundMedical Monitoring Applications for Wearable Computing
Raskovic, D. (2004) · The Computer Journal · doi:10.1093/comjnl/47.4.495 · Cited by 143 · cited 1×
“I. INTRODUCTION Wireless body area networks (WBANs) signify emerging technology with the potential to revolutionize health care by allowing unobtrusive health monitoring for extended periods of time [1][2].”
BackgroundTime synchronization for ZigBee networks
Cox, D., Jovanov, E., & Milenković, A. (2005) · Southeastern Symposium on System Theory (SSST) · doi:10.1109/ssst.2005.1460892 · Cited by 104 · cited 1×
“Even in the case of very infrequent messages (1 message every 2 seconds) our system is synchronized within half of a clock crystal cycle (15 μs) [11].”
Self-citation
Cited by
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Cerebral palsy: clinical care and neurological rehabilitation
Aisen, M. L., Kerkovich, D., Mast, J., Mulroy, S., Wren, T. A., Kay, R. M., & Rethlefsen, S. A. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70176-4 · Cited by 459
Energy Efficient Medium Access Protocol for Wireless Medical Body Area Sensor Networks
Omeni, O., Wong, A. C. W., Burdett, A. J., & Toumazou, C. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003431 · Cited by 322
Systems and WBANs for Controlling Obesity
Mohammed, M. S., Sendra, S., Lloret, J., & Bosch, I. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/1564748 · Cited by 162
Metadata
- Authors
- Jovanov, E., Milenkovic, A., OttO, C., De Groen, P., Johnson, B., Warren, S., & Taibi, G.
- Venue
- 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
- Publisher
- IEEE
- Published
- 2005
- Volume
- 2005
- Pages
- 3810-3813
- OpenAlex
- W2151939695
- Cited by
- 173
- References
- 12
- FWCI
- 20.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.