The DOI matches its Crossref record.
ECG Feature Extraction Based on Multiresolution Wavelet Transform
Abstract
In this work, we have developed and evaluated an electrocardiogram (ECG) feature extraction system based on the multi-resolution wavelet transform. ECG signals from Modified Lead II (MLII) are chosen for processing. The result of applying two wavelet filters (D4 and D6) of different length on the signal is compared. The wavelet filter with scaling function more closely to the shape of the ECG signal achieved better detection. In the first step, the ECG signal was de-noised by removing the corresponding wavelet coefficients at higher scales. Then, QRS complexes are detected and each complex is used to locate the peaks of the individual waves, including onsets and offsets of the P and T waves which are present in one cardiac cycle. We evaluated the algorithm on MIT-BIH Database, the manually annotated database, for validation purposes. The proposed QRS detector achieved sensitivity of 75. 2 % 18 . 99 .. and a positive predictivity of 45 . 4 % 00 . 98 .. over the validation database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Al’Aref, S. J., Anchouche, K., Singh, G., Slomka, P. J., Kolli, K. K., Kumar, A., Pandey, M., Maliakal, G., van Rosendael, A. R., Beecy, A. N., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy404 · Cited by 534
Denoising of ECG signals based on noise reduction algorithms in EMD and wavelet domains
Kabir, M. A., & Shahnaz, C. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.11.003 · Cited by 444
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Metadata
- Authors
- Mahmoodabadi, S. Z., Ahmadian, A., Abolhasani, M. D., Eslami, M., & Bidgoli, J. H.
- Venue
- 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
- Publisher
- IEEE
- Published
- 2005
- Volume
- 2005
- Pages
- 3902-3905
- OpenAlex
- W2157335198
- Cited by
- 184
- References
- 0
- FWCI
- 20.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG Feature Extraction Based on Multiresolution Wavelet Transform. https://app.cochat.ai/papers/10.1109/iembs.2005.1615314
- The paper
- Mahmoodabadi, S. Z., Ahmadian, A., Abolhasani, M. D., Eslami, M., & Bidgoli, J. H. (2005). ECG Feature Extraction Based on Multiresolution Wavelet Transform. 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference. https://doi.org/10.1109/iembs.2005.1615314
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.