Monitoring of Respiration and Heartbeat during Sleep using a Flexible Piezoelectric Film Sensor and Empirical Mode Decomposition
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Cardio-respiratory monitoring during sleep is one of the basic means for assessment of personal health, and has been widely used in diagnosis of sleep disorders. This paper proposes a novel method for non-invasive and unconstrained measurement of respiration and heartbeat during sleep. A flexible piezoelectric film sensor made of aluminum nitride (AlN) material is used in this study. This sensor measures pressure fluctuation due to respiration and heartbeat on the contact surface when a subject is lying on it. Since the AlN film sensor has good sensitivity, the pressure fluctuation measured can be further separated into signals corresponding to respiration and heartbeat, respectively. In the proposed method, the signal separation is achieved using an algorithm based on empirical mode decomposition (EMD). Experiments have been conducted with three subjects. The experimental results show that respiration and heartbeat signals can be successfully obtained with the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computer based sleep recording and analysis
Penzel, T., & Conradt, R. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0087 · Cited by 235
Chee, Y., Han, J., Youn, J., & Park, K. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/007 · Cited by 111 · cited 2×
“Alternatively, attempts have been made to measure pressure fluctuation induced by respiration and heartbeat during sleep, using air mattresses [4], [5], an under-pillow sensor [6], and pressure sensors [7], [8].”
BackgroundMethod
Cited by
Obstructive Sleep Apnea Screening Using a Piezo-Electric Sensor
Erdenebayar, U., Park, J.-U., Jeong, P., & Lee, K.-J. (2017) · Journal of Korean Medical Science · doi:10.3346/jkms.2017.32.6.893 · Cited by 31
A Continuous Respiratory Monitoring System Using Ultrasound Piezo Transducer
Shahshahani, A., Bhadra, S., & Zilic, Z. (2018) · 2018 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2018.8351359 · Cited by 19
“[3] reported a direct method based on aluminum nitride piezoelectric film that monitors the waveform.”
MethodPiezoelectric based Biosignal Transmission using Xbee
Jalil, M., Al, M., Saleh, A., Al, O., Ahmed, S., Shakhatreh, W., & Al, M. (2018) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2018.090836
Metadata
- Authors
- Bu, N., Ueno, N., & Fukuda, O.
- Venue
- 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2007-08
- Volume
- 2007
- Pages
- 1362-1366
- ISSN
- 1557-170X (ISSN-L)
- OpenAlex
- W2117390776
- Cited by
- 86
- References
- 2
- FWCI
- 9.19
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring of Respiration and Heartbeat during Sleep using a Flexible Piezoelectric Film Sensor and Empirical Mode Decomposition. https://app.cochat.ai/papers/10.1109/iembs.2007.4352551
- The paper
- Bu, N., Ueno, N., & Fukuda, O. (2007). Monitoring of Respiration and Heartbeat during Sleep using a Flexible Piezoelectric Film Sensor and Empirical Mode Decomposition. 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4352551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.