The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Level-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI
Abstract
Glaucoma is a leading cause of permanent blindness. However, disease progression can be limited if detected early. The optic cup-to-disc ratio (CDR) is one of the main clinical indicators of glaucoma, and is currently determined manually, limiting its potential in mass screening. In this paper, we propose an automatic CDR determination method using a variational level-set approach to segment the optic disc and cup from retinal fundus images. The method is a core component of ARGALI, a system for automated glaucoma risk assessment. Threshold analysis is used in preprocessing to estimate the initial contour. Due to the presence of retinal vasculature traversing the disc and cup boundaries which can cause inaccuracies in the detected contours, an ellipse-fitting post-processing step is also introduced. The method was tested on 104 images from the Singapore Malay Eye Study, and it was found the results produced a clinically acceptable variation of up to 0.2 CDR units from the manually graded samples, with potential use in mass screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Cited by
Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation
Fu, H., Cheng, J., Xu, Y., Wong, D. W. K., Liu, J., & Cao, X. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2791488 · Cited by 834
Self-citationSuperpixel Classification Based Optic Disc and Optic Cup Segmentation for Glaucoma Screening
Cheng, J., Liu, J., Xu, Y., Yin, F., Wong, D. W. K., Tan, N.-M., Tao, D., Cheng, C.-Y., Aung, T., & Wong, T. Y. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2247770 · Cited by 593
Self-citationDrishti-GS: Retinal image dataset for optic nerve head(ONH) segmentation
Sivaswamy, J., Krishnadas, S. R., Datt Joshi, G., Jain, M., & Syed Tabish, A. U. (2014) · 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6867807 · Cited by 540
Aquino, A., Gegúndez-Arias, M. E., & Marín, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053042 · Cited by 516
CNNs for automatic glaucoma assessment using fundus images: an extensive validation
Diaz-Pinto, A., Morales, S., Naranjo, V., Köhler, T., Mossi, J. M., & Navea, A. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0649-y · Cited by 435
Metadata
- Authors
- Wong, D. W. K., Liu, J., Lim, J. H., Jia, X., Yin, F., Li, H., & Wong, T. Y.
- Venue
- 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2008-08
- Volume
- 2008
- Pages
- 2266-2269
- OpenAlex
- W2159395868
- Cited by
- 171
- References
- 1
- FWCI
- 12.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Level-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI. https://app.cochat.ai/papers/10.1109/iembs.2008.4649648
- The paper
- Wong, D. W. K., Liu, J., Lim, J. H., Jia, X., Yin, F., Li, H., & Wong, T. Y. (2008). Level-set based automatic cup-to-disc ratio determination using retinal fundus images in ARGALI. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2008.4649648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.