The DOI matches its Crossref record.
An acoustic fall detector system that uses sound height information to reduce the false alarm rate
Abstract
More than one third of about 38 million adults 65 and older fall each year in the United States. To address the above problem we propose to develop an acoustic fall detection system (FADE) that will automatically signal a fall to the monitoring caregiver. As opposed to many existent fall detection systems that require the monitored person to wear devices such as accelerometers or gyroscopes at all times, our system is completely unobtrusive by not requiring any wearable devices. To reduce the false alarm rate we employ an array of acoustic sensors to obtain sound source height information. The sound is considered a false alarm if it comes from a source located at a height higher than 2 feet. We tested our system in a pilot study that consisted of a set of 23 falls performed by a stunt actor during six sessions of about 15 minutes each (1.3 hours in total). The actor was previously trained by our nursing collaborators to fall like an elderly person. The use of height information reduced the false alarm hourly rate from 32 to 5 at a 100% fall detection rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart Homes for Elderly Healthcare—Recent Advances and Research Challenges
Majumder, S., Aghayi, E., Noferesti, M., Memarzadeh-Tehran, H., Mondal, T., Pang, Z., & Deen, M. (2017) · Sensors · doi:10.3390/s17112496 · Cited by 618
Portet, F., Vacher, M., Golanski, C., Roux, C., & Meillon, B. (2013) · Personal and Ubiquitous Computing · doi:10.1007/s00779-011-0470-5 · Cited by 421
Fall detection system using Kinect’s infrared sensor
Mastorakis, G., & Makris, D. (2014) · Journal of Real-Time Image Processing · doi:10.1007/s11554-012-0246-9 · Cited by 356
iFall: An android application for fall monitoring and response
Sposaro, F., & Tyson, G. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5334912 · Cited by 317
A Microphone Array System for Automatic Fall Detection
Li, Y., Ho, K. C., & Popescu, M. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2186449 · Cited by 309
Self-citation
Metadata
- Authors
- Popescu, M., Li, Y., Skubic, M., & Rantz, M.
- Venue
- 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2008-08
- Volume
- 2008
- Pages
- 4628-4631
- OpenAlex
- W2130103019
- Cited by
- 189
- References
- 0
- FWCI
- 6.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An acoustic fall detector system that uses sound height information to reduce the false alarm rate. https://app.cochat.ai/papers/10.1109/iembs.2008.4650244
- The paper
- Popescu, M., Li, Y., Skubic, M., & Rantz, M. (2008). An acoustic fall detector system that uses sound height information to reduce the false alarm rate. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2008.4650244
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.