An acoustic fall detector system that uses sound height information to reduce the false alarm rate
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
More than one third of about 38 million adults 65 and older fall each year in the United States. To address the above problem we propose to develop an acoustic fall detection system (FADE) that will automatically signal a fall to the monitoring caregiver. As opposed to many existent fall detection systems that require the monitored person to wear devices such as accelerometers or gyroscopes at all times, our system is completely unobtrusive by not requiring any wearable devices. To reduce the false alarm rate we employ an array of acoustic sensors to obtain sound source height information. The sound is considered a false alarm if it comes from a source located at a height higher than 2 feet. We tested our system in a pilot study that consisted of a set of 23 falls performed by a stunt actor during six sessions of about 15 minutes each (1.3 hours in total). The actor was previously trained by our nursing collaborators to fall like an elderly person. The use of height information reduced the false alarm hourly rate from 32 to 5 at a 100% fall detection rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Signal Processing 4th Edition
Proakis, J. G., & Manolakis, D. K. (1992) · Cited by 4,689
The costs of fatal and non-fatal falls among older adults
Stevens, J. A., Corso, P. S., Finkelstein, E. A., & Miller, T. R. (2006) · Injury Prevention · doi:10.1136/ip.2005.011015 · Cited by 1,501 · cited 1×
“In spite of extensive fall prevention programs [1], in 2006 there were about 400,000 fall related hospitalization with an estimated direct cost of about $19 billion [2].”
BackgroundEARLY MORTALITY AFTER HIP FRACTURE: IS DELAY BEFORE SURGERY IMPORTANT?
MORAN, C. G., WENN, R. T., SIKAND, M., & TAYLOR, A. M. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200503000-00001 · Cited by 670
Fall detection - Principles and Methods
Noury, N., Fleury, A., Rumeau, P., Bourke, A. K., Laighin, G. O., Rialle, V., & Lundy, J. E. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352627 · Cited by 615 · cited 2×
“The fall detection methods found in the literature [6] are based on two types of devices: wearable and non-wearable.”
BackgroundMethodA Smart and Passive Floor-Vibration Based Fall Detector for Elderly
Alwan, M., Rajendran, P. J., Kell, S., Mack, D., Dalal, S., Wolfe, M., & Felder, R. (2006) · 2006 2nd International Conference on Information & Communication Technologies · doi:10.1109/ictta.2006.1684511 · Cited by 402 · cited 1×
“Among the non-wearable fall detection devices we mention floor vibration sensors [7], video cameras [8] [9], infrared cameras [10], and smart carpets.”
BackgroundRobust sound source localization using a microphone array on a mobile robot
Valin, J.-M., Michaud, F., Rouat, J., & Letourneau, D. (2004) · Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453) · doi:10.1109/iros.2003.1248813 · Cited by 381 · cited 1×
“The signal correlation was computed using the whitened spectrum cross-correlation (rather than common time domain cross-correlation) [18], that is: N / nt 2 i 1 N 0 n 2 1 * 2 1 12 e | ) n ( S || ) n ( S | ) n ( S ) n ( S ) t ( R π − = ∑ = , (2) where S i (n) is the Fourier transform of the signal s…”
MethodFall Detection from Human Shape and Motion History Using Video Surveillance
Rougier, C., Meunier, J., St-Arnaud, A., & Rousseau, J. (2007) · 21st International Conference on Advanced Information Networking and Applications Workshops (AINAW'07) · doi:10.1109/ainaw.2007.181 · Cited by 324 · cited 1×
“Among the non-wearable fall detection devices we mention floor vibration sensors [7], video cameras [8] [9], infrared cameras [10], and smart carpets.”
BackgroundPersons Found in Their Homes Helpless or Dead
Gurley, R. J., Lum, N., Sande, M., Lo, B., & Katz, M. H. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342606 · Cited by 236 · cited 1×
“Moreover, the delay in hospitalization can increase the mortality risk in some clinical conditions [4].”
Background(2006) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789812773661_0008 · Cited by 222
Information Extraction From Sound for Medical Telemonitoring
Istrate, D., Castelli, E., Vacher, M., Besacier, L., & Serignat, J.-F. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.859889 · Cited by 131 · cited 1×
“In [12]-[14] a set of acoustic sensors was used to differentiate between several sound classes such as breaking glass, screams, steps, door sound and human sound.”
BackgroundDalal, S., Alwan, M., Seifrafi, R., Kell, S., & Brown, D. E. (2005) · Cited by 36
Falls, Technology, and Stunt Actors
Rantz, M., Aud, M. A., Alexander, G. L., Wakefield, B. J., Skubic, M., Luke, R. H., Anderson, D. T., & Keller, J. M. (2008) · Journal of Nursing Care Quality · doi:10.1097/01.ncq.0000324581.59557.42 · Cited by 19 · cited 1×
“The falls used in this experiment were performed by a stunt actor [20].”
MethodSelf-citationAutomated Sound Analysis System for Home Telemonitoring using Shifted Delta Cepstral Features
Laydrus, N. C., Eliathamby Ambikairajah, A., & Celler, B. G. (2007) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2007.4288537 · Cited by 18
Cited by
Smart Homes for Elderly Healthcare—Recent Advances and Research Challenges
Majumder, S., Aghayi, E., Noferesti, M., Memarzadeh-Tehran, H., Mondal, T., Pang, Z., & Deen, M. (2017) · Sensors · doi:10.3390/s17112496 · Cited by 618
Portet, F., Vacher, M., Golanski, C., Roux, C., & Meillon, B. (2013) · Personal and Ubiquitous Computing · doi:10.1007/s00779-011-0470-5 · Cited by 421
“Promising research has been done to detect distress situations from speech [20] and to detect a fall using microphone [36].”
BackgroundFall detection system using Kinect’s infrared sensor
Mastorakis, G., & Makris, D. (2014) · Journal of Real-Time Image Processing · doi:10.1007/s11554-012-0246-9 · Cited by 356
iFall: An android application for fall monitoring and response
Sposaro, F., & Tyson, G. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5334912 · Cited by 317
A Microphone Array System for Automatic Fall Detection
Li, Y., Ho, K. C., & Popescu, M. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2186449 · Cited by 309
Self-citation
Metadata
- Authors
- Popescu, M., Li, Y., Skubic, M., & Rantz, M.
- Venue
- 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2008-08
- Volume
- 2008
- Pages
- 4628-4631
- OpenAlex
- W2130103019
- Cited by
- 189
- References
- 13
- FWCI
- 6.95
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.