We present results of cortical activity during phoneme pronunciation, recorded using miniaturized electrocorticography grids with high spatial resolution. A patient implanted with the miniature grid was instructed to audibly pronounce one of four phonemes. For each phoneme, we observed distinct spatial correlation patterns at the 3mm electrode spacing. We applied a support vector machine classification scheme and, for the first time, were able to distinguish discrete phonemes with high accuracy. In addition, we found that sub-regions of our miniature array were specific for distinct pairs of phonemes, showing that cortical phoneme processing occurs at a higher resolution than previously though.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations
Muthukumaraswamy, S. D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00138 · Cited by 697
“While inter-electrode spacings of 3–10 mm are commonly used (Blakely et al., 2008; Jerbi et al., 2009b), it has been demonstrated that an interelectrode distances of ∼1.25 mm would be ideal to avoid undersampling iEEG activity (Freeman et al., 2000).”
BackgroundMethodInfluentialBrain-to-text: decoding spoken phrases from phone representations in the brain
Herff, C., Heger, D., de Pesters, A., Telaar, D., Brunner, P., Schalk, G., & Schultz, T. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00217 · Cited by 297
Pei, X., Barbour, D. L., Leuthardt, E. C., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046028 · Cited by 237
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
“Most studies of speech BCIs using invasive recording techniques, regardless of the neural signals used, have focused on the challenging task of decoding continuous, dynamic speech from the neural representations of formant frequencies [9, 10, 31].”
BackgroundSelf-citationTowards reconstructing intelligible speech from the human auditory cortex
Akbari, H., Khalighinejad, B., Herrero, J. L., Mehta, A. D., & Mesgarani, N. (2019) · Scientific Reports · doi:10.1038/s41598-018-37359-z · Cited by 221
Metadata
- Authors
- Blakely, T., Miller, K. J., Rao, R. P. N., Holmes, M. D., & Ojemann, J. G.
- Venue
- 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2008-08
- Volume
- 2008
- Pages
- 4964-4967
- OpenAlex
- W2118849696
- Cited by
- 89
- References
- 0
- FWCI
- 7.11
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Localization and classification of phonemes using high spatial resolution electrocorticography (ECoG) grids. https://app.cochat.ai/papers/10.1109/iembs.2008.4650328
- The paper
- Blakely, T., Miller, K. J., Rao, R. P. N., Holmes, M. D., & Ojemann, J. G. (2008). Localization and classification of phonemes using high spatial resolution electrocorticography (ECoG) grids. 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2008.4650328
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.