SleepMinder: An innovative contact-free device for the estimation of the apnoea-hypopnoea index
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We describe an innovative sensor technology (SleepMinder) for contact-less and convenient measurement of sleep and breathing in the home. The system is based on a novel non-contact biomotion sensor and proprietary automated analysis software. The biomotion sensor uses an ultra low-power radio-frequency transceiver to sense the movement and respiration of a subject. Proprietary software performs a variety of signal analysis tasks including respiration analysis, sleep quality measurement and sleep apnea assessment. This paper measures the performance of SleepMinder as a device for the monitoring of sleep-disordered breathing (SDB) and the provision of an estimate of the apnoea-hypopnoea index (AHI). The SleepMinder was tested against expert manually scored PSG data of patients gathered in an accredited sleep laboratory. The comparison of SleepMinder to this gold standard was performed across overnight recordings of 129 subjects with suspected SDB. The dataset had a wide demographic profile with the age ranging between 20 and 81 years. Body weight included subjects with normal weight through to the very obese (Body Mass Index: 21-44 kg/m(2)). SDB severity ranged from subjects free of SDB to those with severe SDB (AHI: 0.8-96 events/hours). SleepMinder's AHI estimation has a correlation of 91% and can detect clinically significant SDB (AHI>15) with a sensitivity of 89% and a specificity of 92%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
McNicholas, W. T., Bonsignore, M. R., & the Management Committee of EU COST ACTION B26 (2007) · European Respiratory Journal · doi:10.1183/09031936.00027406 · Cited by 911
Self-citation
Cited by
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
“Our work is closest to prior art that uses RF signals to extract a person’s breathing rate and average heart rate [19, 20, 25, 45, 31, 19, 20, 25, 45, 31, 63, 17, 7].”
ResultContactless Sleep Apnea Detection on Smartphones
Nandakumar, R., Gollakota, S., & Watson, N. (2015) · Proceedings of the 13th Annual International Conference on Mobile Systems, Applications, and Services · doi:10.1145/2742647.2742674 · Cited by 343
Recent Developments in Home Sleep-Monitoring Devices
Kelly, J. M., Strecker, R. E., & Bianchi, M. T. (2012) · ISRN Neurology · doi:10.5402/2012/768794 · Cited by 180
O’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“SleepMinderTM (ResMed Sensor Technologies, Dublin, Ireland) is a device that estimates the severity of OSA using a novel method of interpreting the breathing pattern of subjects during sleep (102).”
MethodSelf-citationGetting More from the Sleep Recording
McNicholas, W. T. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.001 · Cited by 3
Self-citation
Metadata
- Authors
- Zaffaroni, A., de Chazal, P., Heneghan, C., Boyle, P., Mppm, P. R., & McNicholas, W. T.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 7091-9094
- OpenAlex
- W2095872441
- Cited by
- 72
- References
- 3
- FWCI
- 10.43
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.