Falls event detection using triaxial accelerometry and barometric pressure measurement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A falls detection system, employing a Bluetooth-based wearable device, containing a triaxial accelerometer and a barometric pressure sensor, is described. The aim of this study is to evaluate the use of barometric pressure measurement, as a surrogate measure of altitude, to augment previously reported accelerometry-based falls detection algorithms. The accelerometry and barometric pressure signals obtained from the waist-mounted device are analyzed by a signal processing and classification algorithm to discriminate falls from activities of daily living. This falls detection algorithm has been compared to two existing algorithms which utilize accelerometry signals alone. A set of laboratory-based simulated falls, along with other tasks associated with activities of daily living (16 tests) were performed by 15 healthy volunteers (9 male and 6 female; age: 23.7 +/- 2.9 years; height: 1.74 +/- 0.11 m). The algorithm incorporating pressure information detected falls with the highest sensitivity (97.8%) and the highest specificity (96.7%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382 · cited 1×
“wearable devices for clinical applications [4].”
Cited by
Smartphone-Based Solutions for Fall Detection and Prevention: Challenges and Open Issues
Habib, M., Mohktar, M., Kamaruzzaman, S., Lim, K., Pin, T., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140407181 · Cited by 219
“[61]”
Fall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Peetoom, K. K. B., Lexis, M. A. S., Joore, M., Dirksen, C. D., & De Witte, L. P. (2015) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2014.961179 · Cited by 208
Tracking the Evolution of Smartphone Sensing for Monitoring Human Movement
Del Rosario, M., Redmond, S., & Lovell, N. (2015) · Sensors · doi:10.3390/s150818901 · Cited by 198
“In the elderly, wearable sensors have found prominence as a means of detecting falls [11] or estimating the likelihood of future falls via gait analysis [12,13].”
BackgroundMethodSelf-citationAmbient Sensors for Elderly Care and Independent Living: A Survey
Uddin, M. Z., Khaksar, W., & Torresen, J. (2018) · Sensors · doi:10.3390/s18072027 · Cited by 166
“[136] (2009) Fall detection The study was to evaluate barometric pressure along with accelerometer-based fall detection.”
Background
Metadata
- Authors
- Bianchi, F., Redmond, S. J., Narayanan, M. R., Cerutti, S., Celler, B. G., & Lovell, N. H.
- Venue
- 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2009-09
- Volume
- 2009
- Pages
- 6111-6114
- OpenAlex
- W2098422462
- Cited by
- 37
- References
- 1
- FWCI
- 3.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Falls event detection using triaxial accelerometry and barometric pressure measurement. https://app.cochat.ai/papers/10.1109/iembs.2009.5334922
- The paper
- Bianchi, F., Redmond, S. J., Narayanan, M. R., Cerutti, S., Celler, B. G., & Lovell, N. H. (2009). Falls event detection using triaxial accelerometry and barometric pressure measurement. 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2009.5334922
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.