The DOI matches its Crossref record.
PhysioDoloris: a monitoring device for Analgesia / Nociception balance evaluation using Heart Rate Variability analysis
Abstract
Continuous Analgesia / Nociception balance evaluation during general anesthesia could be of precious help for the optimization of analgesic drugs delivery, limiting the risk of toxicity due to the use of opioid drugs, limiting the risk of post operative hyper algesia, and, probably, reducing time of recovery after surgical procedure. Heart Rate Variability analysis has been shown in several studies to measure the Autonomic Nervous System tone, which is strongly influenced by anesthetic drugs. Recording RR series during general anesthesia enabled us to observe that the Respiratory Sinus Arrhythmia pattern changed when a surgical stimulation was painful, even though the patient was not conscious. We have previously developed and evaluated a pain / analgesia measurement algorithm based on the magnitude analysis of the respiratory patterns on the RR series. In this paper, we present the development of a monitoring device (PhysioDoloris), based on the previously described technology, giving in real time an Analgesia Nociception Index (ANI) which can be used during general anesthesia in order to give to the anesthetist, a complementary tool for optimized drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Assessing pain objectively: the use of physiological markers
Cowen, R., Stasiowska, M. K., Laycock, H., & Bantel, C. (2015) · Anaesthesia · doi:10.1111/anae.13018 · Cited by 285
Boselli, E., Musellec, H., Martin, L., Bernard, F., Fusco, N., Guillou, N., Hugot, P., Paqueron, X., Yven, T., & Virot, C. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-0056-5 · Cited by 37
Metadata
- Authors
- Logier, R., Jeanne, M., De jonckheere, J., Dassonneville, A., Delecroix, M., & Tavernier, B.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 1194-1197
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2022925833
- Cited by
- 161
- References
- 0
- FWCI
- 23.00
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PhysioDoloris: a monitoring device for Analgesia / Nociception balance evaluation using Heart Rate Variability analysis. https://app.cochat.ai/papers/10.1109/iembs.2010.5625971
- The paper
- Logier, R., Jeanne, M., De jonckheere, J., Dassonneville, A., Delecroix, M., & Tavernier, B. (2010). PhysioDoloris: a monitoring device for Analgesia / Nociception balance evaluation using Heart Rate Variability analysis. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5625971
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.