Sliding-window motion artifact rejection for Functional Near-Infrared Spectroscopy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Functional Near-Infrared Spectroscopy (fNIR) is an optical brain monitoring technology that tracks changes in hemodynamic responses within the cortex. fNIR uses specific wavelengths of light, introduced at the scalp, to enable the noninvasive measurement of changes in the relative ratios of deoxygenated hemoglobin (deoxy-Hb) and oxygenated hemoglobin (oxy-Hb) during brain activity. This technology allows the design of portable, safe, affordable, noninvasive, and minimally intrusive monitoring systems that can be used to measure brain activity in natural environments, ambulatory and field conditions. However, for such applications fNIR signals can get prone to noise due to motion of the head. Improving signal quality and reducing noise, can be especially challenging for real time applications. Here, we study motion artifact related noise especially due to poor and changing sensor coupling. We have developed a simple and iterative method that can be used to automate the preprocessing of data to identify segments with such noise for exclusion and this method is also suitable for real time applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817 · cited 4×
“Most of these algorithms are developed and modeled for oxy-Hb, deoxy-Hb and blood volume (oxy-Hb + deoxy-Hb) data [9-11], and the remaining algorithms perform analysis on the raw intensity measurements [12, 13 ].”
BackgroundMethodInfluential
Cited by
Optical brain monitoring for operator training and mental workload assessment
Ayaz, H., Shewokis, P. A., Bunce, S., Izzetoglu, K., Willems, B., & Onaral, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.023 · Cited by 650
“1 Hz to attenuate the high frequency noise, respiration and cardiac cycle effects (Ayaz et al., 2010; Izzetoglu et al., 2005).”
InfluentialSelf-citationKesedzic, I., Sarlija, M., Bozek, J., Popovic, S., & Cosic, K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3038032 · Cited by 29
Kable, J. A., Coles, C. D., & Mattson, S. N. (2020) · Developmental Neuropsychology · doi:10.1080/87565641.2020.1712604 · Cited by 14
“An algorithm, the Sliding-window Motion Artifact Rejection (SMAR) (Ayaz et al., 2010, 2011), was then applied to remove motion artifacts in the signal with a window size of 10.”
Method
Metadata
- Authors
- Ayaz, H., Izzetoglu, M., Shewokis, P. A., & Onaral, B.
- Venue
- 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2010-08
- Volume
- 2010
- Pages
- 6567-6570
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2050576536
- Cited by
- 171
- References
- 2
- FWCI
- 22.16
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sliding-window motion artifact rejection for Functional Near-Infrared Spectroscopy. https://app.cochat.ai/papers/10.1109/iembs.2010.5627113
- The paper
- Ayaz, H., Izzetoglu, M., Shewokis, P. A., & Onaral, B. (2010). Sliding-window motion artifact rejection for Functional Near-Infrared Spectroscopy. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.