The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Towards mental stress detection using wearable physiological sensors
Abstract
Early mental stress detection can prevent many stress related health problems. This study aimed at using a wearable sensor system to measure physiological signals and detect mental stress. Three different stress conditions were presented to a healthy subject group. During the procedure, ECG, respiration, skin conductance, and EMG of the trapezius muscles were recorded. In total, 19 physiological features were calculated from these signals. After normalization of the feature values and analysis of correlations among these features, a subset of 9 features was selected for further analysis. Principal component analysis reduced these 9 features to 7 principal components (PCs). Using these PCs and different classifiers, a consistent classification accuracy between stress and non stress conditions of almost 80% was found. This suggests that a promising feature subset was found for future development of a personalized stress monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypothalamic-pituitary-adrenal axis, neuroendocrine factors and stress
Tsigos, C., & Chrousos, G. P. (2002) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(02)00429-4 · Cited by 2,822 · cited 2×
“Stress is known to activate the sympathetic nervous system (SNS) [4].”
BackgroundDetecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Discriminating Stress From Cognitive Load Using a Wearable EDA Device
Setz, C., Arnrich, B., Schumm, J., La Marca, R., Troster, G., & Ehlert, U. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036164 · Cited by 742
Psychophysiological stress and emg activity of the trapezius muscle
Lundberg, U., Kadefors, R., Melin, B., Palmerud, G., Hassmén, P., Engström, M., & Elfsberg Dohns, I. (1994) · International Journal of Behavioral Medicine · doi:10.1207/s15327558ijbm0104_5 · Cited by 381
Cited by
Review on Psychological Stress Detection Using Biosignals
Giannakakis, G., Grigoriadis, D., Giannakaki, K., Simantiraki, O., Roniotis, A., & Tsiknakis, M. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2019.2927337 · Cited by 764
Mentis, A.-F. A., Lee, D., & Roussos, P. (2024) · Molecular Psychiatry · doi:10.1038/s41380-023-02047-6 · Cited by 75
Züger, M., Müller, S. C., Meyer, A. N., & Fritz, T. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3174165 · Cited by 66
Mental Health Monitoring System using Artificial Intelligence: A Review
Mody, V., & Mody, V. (2019) · 2019 IEEE 5th International Conference for Convergence in Technology (I2CT) · doi:10.1109/i2ct45611.2019.9033652 · Cited by 52
Beyond Mobile Apps: A Survey of Technologies for Mental Well-Being
Woodward, K., Kanjo, E., Brown, D. J., McGinnity, T. M., Inkster, B., Macintyre, D. J., & Tsanas, A. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2020.3015018 · Cited by 18
Metadata
- Authors
- Wijsman, J., Grundlehner, B., Liu, H., Hermens, H., & Penders, J.
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 1798-1801
- OpenAlex
- W2072454120
- Cited by
- 194
- References
- 4
- FWCI
- 6.64
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards mental stress detection using wearable physiological sensors. https://app.cochat.ai/papers/10.1109/iembs.2011.6090512
- The paper
- Wijsman, J., Grundlehner, B., Liu, H., Hermens, H., & Penders, J. (2011). Towards mental stress detection using wearable physiological sensors. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6090512
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.