Joint power optimization of data center network and servers with correlation analysis

Zheng, Kuangyu, Wang, Xiaodong, Li, Li, Wang, Xiaorui · 2014 · IEEE INFOCOM 2014 - IEEE Conference on Computer Communications
Cited by 130

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Data center power optimization has recently received a great deal of research attention. For example, server consolidation has been demonstrated as one of the most effective energy saving methodologies. Likewise, traffic consolidation has also been recently proposed to save energy for data center networks (DCNs). However, current research on data center power optimization focuses on servers and DCN separately. As a result, the optimization results are often inferior, because server consolidation without considering the DCN may cause traffic congestion and thus degraded network performance. On the other hand, server consolidation may change the DCN topology, allowing new opportunities for energy savings. In this paper, we propose PowerNetS, a power optimization strategy that leverages workload correlation analysis to jointly minimize the total power consumption of servers and the DCN. The design of PowerNetS is based on the key observations that the workloads of different servers and DCN traffic flows do not peak at exactly the same time. Thus, more energy savings can be achieved if the workload correlations are considered in server and traffic consolidations. In addition, PowerNetS considers the DCN topology during server consolidation, which leads to less inter-server traffic and thus more energy savings and shorter network delays. We implement PowerNetS on a hardware testbed composed of 10 virtual switches configured with a production 48-port OpenFlow switch and 6 servers. Our empirical results with Wikipedia, Yahoo!, and IBM traces demonstrate that PowerNetS can save up to 51.6% of energy for a data center. PowerNetS also outperforms two state-of-the-art baselines by 44.3% and 15.8% on energy savings, respectively. Our simulation results with 72 switches and 122 servers also show the superior energy efficiency of PowerNetS over the baselines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/infocom.2014.6848207

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Untitled work

    (2010) · doi:10.5555/1855711.1855728 · Cited by 970

Cited by

See all 130

Metadata

Authors
Zheng, K., Wang, X., Li, L., & Wang, X.
Venue
IEEE INFOCOM 2014 - IEEE Conference on Computer Communications
Publisher
IEEE
Published
2014-04
Pages
2598-2606
OpenAlex
W2001065285
Cited by
130
References
1
FWCI
10.37
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.