DC microgrids in buildings and data centers
Abstract
The debate on the use of Direct Current (DC) as a power distribution means has been raging for decades. Recently, one focus of the discussion has been the data center. For various reasons, AC remains the preferred method of power distribution in the data center, despite some disadvantages inherent to AC power. This is particularly interesting when one considers the fact that almost all of the critical payloads in the data center are DC loads. The recent drive toward Smart Grid technology coupled with the potential advantages DC distribution can offer opens the door for serious discussion on the merits of DC microgrids as a viable distribution alternative in the building space and, in particular, the data center. This paper will examine the advantages, issues and challenges of the use of DC for this purpose. Further, the paper will look at the current activity in the standards community, with particular attention given to the current ETSI and EMerge Alliance efforts to formulate a standard that deals with 380Vdc power distribution. The paper also will examine the ability of a DC microgrid to facilitate renewable energy use as well as provide high degrees of critical load availability. It will include a discussion of potential system topologies as well as various proof- of-concept sites currently under way. Finally, the current status of safety issues in the use of higher voltage distribution in building spaces will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
DC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
AC and DC technology in microgrids: A review
Planas, E., Andreu, J., Gárate, J. I., Martínez de Alegría, I., & Ibarra, E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.11.067 · Cited by 500
A review on overall control of DC microgrids
Kumar, J., Agarwal, A., & Agarwal, V. (2019) · Journal of Energy Storage · doi:10.1016/j.est.2018.11.013 · Cited by 257
99% Efficient Isolated Three-Phase Matrix-Type DAB Buck–Boost PFC Rectifier
Schrittwieser, L., Leibl, M., & Kolar, J. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2914488 · Cited by 169
Metadata
- Authors
- Becker, D. J., & Sonnenberg, B. J.
- Venue
- 2011 IEEE 33rd International Telecommunications Energy Conference (INTELEC)
- Publisher
- IEEE
- Published
- 2011-10
- Pages
- 1-7
- OpenAlex
- W2082240199
- Cited by
- 178
- References
- 0
- FWCI
- 10.20
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DC microgrids in buildings and data centers. https://app.cochat.ai/papers/10.1109/intlec.2011.6099725
- The paper
- Becker, D. J., & Sonnenberg, B. J. (2011). DC microgrids in buildings and data centers. 2011 IEEE 33rd International Telecommunications Energy Conference (INTELEC). https://doi.org/10.1109/intlec.2011.6099725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.