Misalignment Detection of Rotor System Based on Adaptive Input-output Model Identification of Motor Speed
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Traditionally, the misalignment detection of rotor system is based on vibration signal analysis. However, the vibration-based method is high-cost and limited by the installation space due to the need of vibration sensors. To solve the problems, this paper employs the speed signal which has already been collected for motor control to detect the misalignment. Furthermore, fault features, the speed ripples related to rotation frequency frand its second-harmonic 2fr, are modeled using input-output identification method. Compared to Fast Fourier Transform, the amount of data needed is greatly reduced. The effectiveness of the proposed method is validated with the experimental platform.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In [171] and [174], the FFT analysis of the PMSM motor speed signal is used to detect misalignment.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [174]
Citations
Cites
Jalan, A. K., & Mohanty, A. R. (2009) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2009.07.014 · Cited by 269
Xu, M., & Marangoni, R. D. (1994) · Journal of Sound and Vibration · doi:10.1006/jsvi.1994.1405 · Cited by 258 · cited 1×
“With Euler formula, the relationship between the angular speeds of load side and motor side can be formulated as([12])”
BackgroundDYNAMIC RESPONSE OF TWO ROTORS CONNECTED BY RIGID MECHANICAL COUPLING WITH PARALLEL MISALIGNMENT
AL-HUSSAIN, K. M., & REDMOND, I. (2002) · Journal of Sound and Vibration · doi:10.1006/jsvi.2001.3866 · Cited by 173
Detection and monitoring of coupling misalignment in rotors using torque measurements
Reddy, M. C. S., & Sekhar, A. S. (2014) · Measurement · doi:10.1016/j.measurement.2014.10.031 · Cited by 81
Angular misalignment in induction motors with flexible coupling
Bossio, J. M., Bossio, G. R., & Angelo, C. H. D. (2009) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2009.5414696 · Cited by 58 · cited 1×
“[8] and [9] have studied the theory of shaft misalignment diagnosis using current spectral analysis, which indicated that sideband frequencies, e r f f ± ,”
BackgroundAntonino-Daviu, J., & Popaleny, P. (2018) · 2018 XIII International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506949 · Cited by 39
Virtual fault simulation for diagnosis of shaft misalignment of rotating machine
Behera, D. P., Behera, R., & Naikan, V. N. A. (2014) · International Conference on Advances in Computing, Communications and Informatics (ICACCI) · doi:10.1109/icacci.2014.6968225 · Cited by 10 · cited 1×
“The most widely applied mechanical faults detection method is the vibration analysis for its effectiveness [6-7].”
MethodLiu, X., Liang, D., Du, J., Yu, Y., Yang, X., & Luo, Z. (2014) · 2014 17th International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2014.7013721 · Cited by 9 · cited 1×
“[10] employed the electromagnetic torque of a permanent magnet synchronous motor (PMSM) to detect the parallel misaligned fault.”
MethodDiagnosis Method for Hydro-generator Rotor Fault Based on Stochastic Resonance
Li, J., Wang, L., & Li, Y. (2019) · IEEE Conference on Prognostics and Health Management · doi:10.1109/icphm.2019.8819379 · Cited by 8 · cited 1×
“Typical faults of rotating machinery mainly include the load unbalance, coupling misalignment, bearing damage, looseness fault [2], etc.”
Background
Research works printed but not linked: 3
- li, 2015, Theoretical and Experimental Study on Dynamics of Rotor-Bearing System with the Faults of Coupling Misalignment[J], Zhendong Ceshi Yu Zhenduan/Journal of Vibration Measurement and Diagnosis, 35, 345
- ming, 2012, Nonlinear dynamics of asymmetric flexible generator rotor system with parallel misalignment[J], Proceedings of the CSEE, 32, 111
- cabanas, 1996, Shaft misalignment diagnosis of induction motors using current spectral analysis: a theoretical approach, International Conference on Electrical Machines-ICEM
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[171], [174] Rotational speed FFT 2fr NINV, PM and AM [174] SC, RS, AM [171]”
BackgroundMethodCurrent- and Vibration-Based Detection of Misalignment Faults in Synchronous Reluctance Motors
Navarro-Navarro, Á., Biot-Monterde, V., Ruiz-Sarrio, J. E., & Daviu, J. A. A. (2025) · Machines · doi:10.3390/machines13040319 · Cited by 18
“In [17,18], FFT analysis of the speed signal was utilized to identify misalignment, revealing an increase in the amplitudes of the f r and 2 f r components.”
Navarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
“In [128,129], FFT analysis of the speed is used to detect misalignment.”
MethodOverview of IoT Security Challenges and Sensors Specifications in PMSM for Elevator Applications
Vlachou, E. I., Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12120839 · Cited by 13
Navarro-Navarro, Á., Biot-Monterde, V., Ruiz-Sarrio, J. E., & Daviu, J. A. A. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362465 · Cited by 4
“In [10] and [11], the FFT analysis of the speed is used to detect misalignment.”
Method
Metadata
- Authors
- Chai, N., Yang, M., Ren, B., Huang, X., & Xu, D.
- Affiliations
- Harbin Institute of Technology (CN)
- Venue
- 2020 IEEE 9th International Power Electronics and Motion Control Conference (IPEMC2020-ECCE Asia)
- Publisher
- IEEE
- Published
- 2020-11-29
- Pages
- 2266-2271
- OpenAlex
- W3135704980
- Cited by
- 6
- References
- 9
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1
- FWCI
- 1.50
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- International Power Electronics and Motion Control Conference (EPE-PEMC) (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- adaptive identification, speed ripple
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Misalignment Detection of Rotor System Based on Adaptive Input-output Model Identification of Motor Speed. https://app.cochat.ai/papers/10.1109/ipemc-ecceasia48364.2020.9367979
- The paper
- Chai, N., Yang, M., Ren, B., Huang, X., & Xu, D. (2020). Misalignment Detection of Rotor System Based on Adaptive Input-output Model Identification of Motor Speed. 2020 IEEE 9th International Power Electronics and Motion Control Conference (IPEMC2020-ECCE Asia). https://doi.org/10.1109/ipemc-ecceasia48364.2020.9367979
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.