The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An autonomous, underactuated exoskeleton for load-carrying augmentation
Abstract
Metabolic studies have shown that there is a metabolic cost associated with carrying load (T. M. Griffen, et al., 2003). In previous work, a lightweight, underactuated exoskeleton has been described that runs in parallel to the human and supports the weight of a payload (C. J. Walsh, et al., 2006). A state-machine control strategy is written based on joint angle and ground-exoskeleton force sensing to control the joint actuation at this exoskeleton hip and knee. The joint components of the exoskeleton in the sagittal plane consist of a force-controllable actuator at the hip, a variable-damper mechanism at the knee and a passive spring at the ankle. The control is motivated by examining human walking data. Positive, non-conservative power is added at the hip during the walking cycle to help propel the mass of the human and payload forward. At the knee, the damper mechanism is turned on at heel strike as the exoskeleton leg is loaded and turned off during terminal stance to allow knee flexion. The passive spring at the ankle engages in controlled dorsiflexion to store energy that is later released to assist in powered plantarflexion. Preliminary studies show that the state machines for the hip and knee work robustly and that the onset of walking can be detected in less than one gait cycle. Further, it is found that an efficient, underactuated leg exoskeleton can effectively transmit payload forces to the ground during the walking cycle
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 2×
“The joint components of the exoskeleton in the sagittal plane consist of a force-controllable actuator at the hip, a variable-damper mechanism at the knee and a passive spring at the ankle.”
Background
Cited by
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Self-citationA QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Self-citationThe exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Review of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Metadata
- Authors
- Walsh, C., Pasch, K., & Herr, H.
- Venue
- 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2006-10
- Pages
- 1410-1415
- OpenAlex
- W2086473770
- Cited by
- 162
- References
- 1
- FWCI
- 6.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An autonomous, underactuated exoskeleton for load-carrying augmentation. https://app.cochat.ai/papers/10.1109/iros.2006.281932
- The paper
- Walsh, C., Pasch, K., & Herr, H. (2006). An autonomous, underactuated exoskeleton for load-carrying augmentation. 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems. https://doi.org/10.1109/iros.2006.281932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.