GelSlim: A High-Resolution, Compact, Robust, and Calibrated Tactile-sensing Finger
Open accessAbstract
This work describes the development of a high-resolution tactile-sensing finger for robot grasping. This finger, inspired by previous GelSight sensing techniques (Johnson and Adelson 2009), features an integration that is slimmer, more robust, and with more homogeneous output than previous vision-based tactile sensors. To achieve a compact integration, we redesign the optical path from illumination source to camera by combining light guides and an arrangement of mirror reflections. We parameterize the optical path with geometric design variables and describe the tradeoffs between the finger thickness, camera depth of field, and size of the tactile sensing area. The sensor sustains the wear from continuous use - and abuse - in grasping tasks by combining tougher materials for the compliant gel, a textured fabric skin, a structurally rigid body, and a calibration process that maintains homogeneous illumination and contrast of the tactile images during use. Finally, we evaluate the sensor's durability along four metrics that track the signal quality during more than 3000 grasping experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis and Observations From the First Amazon Picking Challenge
Correll, N., Bekris, K. E., Berenson, D., Brock, O., Causo, A., Hauser, K., Okada, K., Rodriguez, A., Romano, J. M., & Wurman, P. R. (2018) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2016.2600527 · Cited by 425 · cited 1×
“In cluttered environments like a pantry or a warehouse storage cell, as in the Amazon Robotics Challenge [7], a robot faces the challenge of singulating target objects from a tightly-packed collection of items.”
Background
Cited by
Lambeta, M., Chou, P.-W., Tian, S., Yang, B., Maloon, B., Most, V. R., Stroud, D., Santos, R., Byagowi, A., Kammerer, G., et al. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2977257 · Cited by 553
VITO-Transformer: A Visual-Tactile Fusion Network for Object Recognition
Li, B., Bai, J., Qiu, S., Wang, H., & Guo, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3326241 · Cited by 39
Sparsh: Self-supervised touch representations for vision-based tactile sensing
Higuera, C., Sharma, A., Bodduluri, C. K., Fan, T., Lancaster, P., Kalakrishnan, M., Kaess, M., Boots, B., Lambeta, M., Wu, T., et al. (2024) · arXiv · doi:10.48550/arxiv.2410.24090 · Cited by 4
Metadata
- Authors
- Donlon, E., Dong, S., Liu, M., Li, J., Adelson, E., & Rodriguez, A.
- Venue
- 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS)
- Publisher
- IEEE
- Published
- 2018-10
- Pages
- 1927-1934
- OpenAlex
- W2793598667
- Cited by
- 332
- References
- 1
- FWCI
- 34.84
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: GelSlim: A High-Resolution, Compact, Robust, and Calibrated Tactile-sensing Finger. https://app.cochat.ai/papers/10.1109/iros.2018.8593661
- The paper
- Donlon, E., Dong, S., Liu, M., Li, J., Adelson, E., & Rodriguez, A. (2018). GelSlim: A High-Resolution, Compact, Robust, and Calibrated Tactile-sensing Finger. 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). https://doi.org/10.1109/iros.2018.8593661
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).