Non-uniform patch sampling with deep convolutional neural networks for white matter hyperintensity segmentation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Convolutional neural networks (CNN) have been widely used for visual recognition tasks including semantic segmentation of images. While the existing methods consider uniformly sampled single-or multi-scale patches from the neighborhood of each voxel, this approach might be sub-optimal as it captures and processes unnecessary details far away from the center of the patch. We instead propose to train CNNs with non-uniformly sampled patches that allow a wider extent for the sampled patches. This results in more captured contextual information, which is in particular of interest for biomedical image analysis, where the anatomical location of imaging features are often crucial. We evaluate and compare this strategy for white matter hyperintensity segmentation on a test set of 46 MRI scans. We show that the proposed method not only outperforms identical CNNs with uniform patches of the same size (0.780 Dice coefficient compared to 0.736), but also gets very close to the performance of an independent human expert (0.796 Dice coefficient).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Jenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
Theano: new features and speed improvements
Bastien, F., Lamblin, P., Pascanu, R., Bergstra, J., Goodfellow, I., Bergeron, A., Bouchard, N., Warde-Farley, D., & Bengio, Y. (2012) · arXiv · doi:10.48550/arxiv.1211.5590 · Cited by 1,005 · cited 1×
“We utilize the Theano library [7] for the implementation.”
Method
Cited by
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
“To tackle this, Ghafoorian et al. (2016b) used non-uniformly sampled patches by gradually lowering sampling rate in patch sides to span a larger context.”
MethodSelf-citationNair, T., Precup, D., Arnold, D. L., & Arbel, T. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101557 · Cited by 451
Ghafoorian, M., Karssemeijer, N., Heskes, T., van Uden, I. W. M., Sanchez, C. I., Litjens, G., de Leeuw, F.-E., van Ginneken, B., Marchiori, E., & Platel, B. (2017) · Scientific Reports · doi:10.1038/s41598-017-05300-5 · Cited by 236
Self-citationGuerrero, R., Qin, C., Oktay, O., Bowles, C., Chen, L., Joules, R., Wolz, R., Valdés-Hernández, M. C., Dickie, D. A., Wardlaw, J., et al. (2018) · NeuroImage: Clinical · doi:10.1016/j.nicl.2017.12.022 · Cited by 223
Iqbal, S., N. Qureshi, A., Li, J., & Mahmood, T. (2023) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-023-09899-9 · Cited by 210
Metadata
- Authors
- Ghafoorian, M., Karssemeijer, N., Heskes, T., van Uder, I. W. M., de Leeuw, F. E., Marchiori, E., van Ginneken, B., & Platel, B.
- Venue
- 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI)
- Publisher
- IEEE
- Published
- 2016-04
- Pages
- 1414-1417
- OpenAlex
- W2422852360
- Cited by
- 68
- References
- 3
- FWCI
- 3.41
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.