Susceptibility to misdiagnosis of adversarial images by deep learning based retinal image analysis algorithms
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Deep learning algorithms, typically implemented as Convolutional Neural Networks (CNNs), in recent years have gained traction in medical image analysis. The majority of CNNs employed in retinal image diagnosis applications are image-based; wherein input is the retinal image and output is the classification/diagnosis, resulting in a blackbox like algorithm. In contrast, hybrid lesion-based algorithms employ multiple CNN-based detectors to categorically detect various lesions in the image, and final diagnosis is computed from combination of detector outputs. Such algorithms are more physiologically plausible and provides explainability of the final prediction through intermediate detector outputs. Both classes of algorithms have reported equal diagnostic performance and outperform clinical experts in detecting referable diabetic retinopathy (rDR). However, CNNs are sensitive to adversarial images where a limited number of pixels are modified by a fraction of intensity while preserving global image context; leading to CNN misclassification. We compared diagnostic accuracy of the two classes of algorithms on adversarial images generated from rDR retinal images and results show that image-based CNNs are significantly more susceptible to adversarial images than hybrid lesion-based algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Delving into Transferable Adversarial Examples and Black-box Attacks
Liu, Y., Chen, X., Liu, C., & Song, D. (2016) · arXiv · doi:10.48550/arxiv.1611.02770 · Cited by 1,310
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Self-citationEyePACS: An Adaptable Telemedicine System for Diabetic Retinopathy Screening
Cuadros, J., & Bresnick, G. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300315 · Cited by 390 · cited 1×
“504,906 images were obtained from the Eyepacs dataset [13] for training the CNNs used in the experiments.”
Method
Cited by
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
“These physiologically plausible algorithms have been shown to be more robust to small perturbations in input images, possibly because they have partially dependent, and thus redundant detectors.(39) Additionally, microaneurysms have been long recognized as the earliest retinal sign of DR that is seen on ophthalmoscopi…”
BackgroundSelf-citationIdentifying Ethical Considerations for Machine Learning Healthcare Applications
Char, D. S., Abràmoff, M. D., & Feudtner, C. (2020) · The American Journal of Bioethics · doi:10.1080/15265161.2020.1819469 · Cited by 415
“Even when post hoc explainability can be provided, such black box, neural-network based systems are vulnerable to “ catastrophic failures ” and implicit biases in the training sets compared to more explainable ML architectures (Finlayson et al. 2019; Shah et al. 2018).”
BackgroundSelf-citationAbràmoff, M. D., Tobey, D., & Char, D. S. (2020) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2020.02.022 · Cited by 140
Self-citationFoundational Considerations for Artificial Intelligence Using Ophthalmic Images
Abràmoff, M. D., Cunningham, B., Patel, B., Eydelman, M. B., Leng, T., Sakamoto, T., Blodi, B., Grenon, S. M., Wolf, R. M., Manrai, A. K., et al. (2022) · Ophthalmology · doi:10.1016/j.ophtha.2021.08.023 · Cited by 96
Self-citationAutomated and computer-assisted detection, classification, and diagnosis of diabetic retinopathy
Abràmoff, M. D., Leng, T., Ting, D. S. W., Rhee, K., Horton, M. B., Brady, C. J., & Chiang, M. F. (2020) · Telemedicine and e-Health · doi:10.1089/tmj.2020.0008 · Cited by 30
“23,24”
Self-citationAbramoff, M. D., Mortensen, Z., & Tava, C. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.765936 · Cited by 6
Metadata
- Authors
- Shah, A., Lynch, S., Niemeijer, M., Amelon, R., Clarida, W., Folk, J., Russell, S., Wu, X., & Abramoff, M. D.
- Venue
- 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018)
- Publisher
- IEEE
- Published
- 2018-04
- Pages
- 1454-1457
- OpenAlex
- W2807189427
- Cited by
- 38
- References
- 4
- FWCI
- 10.26
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.