Economic model predictive control for building energy systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The objective of this study is to demonstrate the effectiveness of model predictive control (MPC) in reducing the energy and demand costs for buildings in an electricity grid with time-of-use pricing and demand charges. A virtual model for a single floor, multi-zone commercial building equipped with a variable air volume (VAV) cooling system is built by Energyplus. Real-time data exchange between Energyplus and Matlab controller is realized by introducing the building controls virtual test bed (BCVTB) as a middleware. System identification technique is implemented to obtain the zone temperature and power model, which are to be used in the MPC framework. MPC with an economic objective function is formulated as a linear programming problem and solved. Pre-cooling effect during off-peak period and autonomous cooling discharging from the building thermal mass during on-peak period can be observed in a continuous weekly simulation. Cost savings brought by MPC are given by comparing with the baseline and other pre-programmed control strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Demand Response under the Smart Grid and Market paradigms
Rahimi, F., & Ipakchi, A. (2010) · 2010 Innovative Smart Grid Technologies (ISGT) · doi:10.1109/isgt.2010.5434754 · Cited by 81 · cited 1×
“is an approach to incent end users to change electric usage from their regular patterns, in response to the time-varying price of electricity [ 2 ].”
Background
Cited by
Afram, A., Janabi-Sharifi, F., Fung, A. S., & Raahemifar, K. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.012 · Cited by 655
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
“However, those processes can be treated as a Linear Time-Invariant (LTI) system, under proper assumptions and simplifications in the control-oriented model (e.g., RC networks with fixed material features and linearized radiative heat transfer coefficient).”
Review of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629
Review of modeling methods for HVAC systems
Afram, A., & Janabi-Sharifi, F. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2014.03.055 · Cited by 479
Demand reduction in building energy systems based on economic model predictive control
Ma, J., Qin, J., Salsbury, T., & Xu, P. (2012) · Chemical Engineering Science · doi:10.1016/j.ces.2011.07.052 · Cited by 373
Self-citation
Metadata
- Authors
- Ma, J., Qin, S. J., Li, B., & Salsbury, T.
- Venue
- ISGT 2011
- Publisher
- IEEE
- Published
- 2011-01
- Pages
- 1-6
- OpenAlex
- W2171923246
- Cited by
- 116
- References
- 1
- FWCI
- 43.36
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.