A comprehensive solar PV hosting capacity in MV and LV radial distribution networks
Abstract
With the increasing adoption of solar PV generation system, it is essential to analyze the impacts to the distribution system especially if PV units is installed in both MV and LV network. This paper develops a methodology that determines the solar PV hosting capacity of a distribution network considering the effect between the interactions of MV and LV network at different voltage levels. A comprehensive approach was used including complete LV network modeling characteristics. The interaction between the MV and LV network offers an advantage to other approaches described in the literature. A modified 25-bus test system with complete MV and LV network model was tested and an integrated MV-LV power flow solution was used to analyze the impacts on its interactions. Peak and off-peak load conditions of different customer types were also considered. Aggregate installation was examined and it was shown that single solar PV installation is sufficient for the hosting capacity quantification. Also, LV network hosting capacity installations have minimal effect on the MV network. Results show that the main limitation of MV hosting capacity is the LV network voltage problems.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The deterministic method considers worst-case scenarios to determine HC due to the extreme impact of uncertain parameters.
“The deterministic method also considers the worst-case scenarios to determine the HC due to the extreme impact of uncertain parameters [60][61][62].”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [60]
Cited by
Sorted by citations
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71 · see citing works
- Authors
- Navarro, B. B., & Navarro, M. M.
- Affiliations
- Technological Institute of the Philippines-Quezon City (PH)
- Venue
- 2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)
- Publisher
- IEEE
- Published
- 2017-09
- Pages
- 1-6
- OpenAlex
- W2783144023
- Cited by
- 38
- References
- 0
- Citations by year
- 2025: 3 · 2024: 7 · 2023: 11 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 3 · 2018: 5
- FWCI
- 4.26
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE PES Innovative Smart Grid Technologies Europe (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
- Physical Sciences › Engineering › Control and Systems Engineering › Thermal Analysis in Power Transmission
- Keywords
- radial distribution systems, customer types
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review